Frictional power losses of high-speed and heavy-load herringbone gearboxes increase the temperature of the gearbox. Thus, real-time surface temperature measurement is significant for evaluating the gearbox lubrication design. A rotating gear test rig with an infrared pyrometer is developed in this paper to conduct real-time and accurate temperature measurements of the transverse plane of the oil-jet-lubrication herringbone gear. First, the influencing factors and measuring errors of surface temperature are analyzed using the infrared pyrometer. The emissivity of the measured surface of a gear tooth painted with matte black is experimentally calibrated. Second, the temperature measurement tests of the oil-jet-lubrication herringbone gear under different conditions are carried out. Measurement errors resulting from purge air pressure, purge air temperature, and oil-jet temperature are also experimentally studied. The results indicate that the purge gas flow can reduce the measurement errors of the infrared pyrometer resulting from oil mist with an appropriate purge air pressure and purge air temperature. Finally, a mathematical curve-fitting of the measurement results between the infrared pyrometer and thermocouple is carried out. The calculated temperatures by the curve-fitting formula are compared with the measured thermocouple temperature, with the relative differences being less than 1 °C. Thus, the curve-fitting formula is credible for the real-time measurement of surface temperature, while the relevant measuring method is also valuable for engineering applications of high-speed gear systems under oil-jet-lubrication conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0098729DOI Listing

Publication Analysis

Top Keywords

infrared pyrometer
16
purge air
16
temperature measurement
12
oil-jet-lubrication herringbone
12
herringbone gear
12
surface temperature
12
temperature
11
transverse plane
8
plane oil-jet-lubrication
8
measurement errors
8

Similar Publications

The objectives of this study were: (i) to verify and compare the coat surface temperature (CST) of regions of interest (ROI) measured through infrared pyrometer (IRP) and thermography (IRT) under two environmental conditions, to evaluate (ii) reliability and (iii) sensitivity of the two infrared equipments to the environmental effect. Twenty hair ewes (Ovis aries), multiparous, non-lactating, non-pregnant, with body weight 59.38 ± 6.

View Article and Find Full Text PDF

In this study, through the utilization of the sol-gel combustion tactic, gadolinium (Gd)-doped cerium oxide (CeO), CeGdO ( = 0.00, 0.10, 0.

View Article and Find Full Text PDF

Cylindrical Inconel 718 specimens were fabricated via a blown-powder, laser-directed energy deposition (DED-L) additive manufacturing (AM) process equipped with a dual thermal monitoring system to learn key process-structure relationships. Thermographic inspection of the heat affected zone (HAZ) and melt pool was performed with different layer-to-layer time intervals of ~0 s, 5 s, and 10 s, using an infrared camera and dual-wavelength pyrometer, respectively. Maximum melt pool temperatures were found to increase with layer number within a substrate affected zone (SAZ), and then asymptotically decrease.

View Article and Find Full Text PDF

The thermal process of a (001) silicon wafer subjected to a continuous-wave (CW) laser and 100-10000 Hz pulsed laser irradiation is investigated experimentally and numerically. The temperature evolution of the spot center is measured using an infrared radiation pyrometer. The waveforms of the temperature evolution curves provide valuable information about melting, solidification, vaporization, and fracture.

View Article and Find Full Text PDF

InAsSb Photodiode Fibre Optic Thermometry for High-Speed, near-Ambient Temperature Measurements.

Sensors (Basel)

November 2023

Sensor Systems Group, Department of Electrical & Electronic Engineering, University of Sheffield, Sheffield S1 4ET, UK.

Infrared radiation thermometers (IRTs) overcome many of the limitations of thermocouples, particularly responsiveness and calibration drift. The main challenge with radiation thermometry is the fast and reliable measurement of temperatures close to room temperature. A new IRT which is sensitive to wavelengths between 3 μm and 11 μm was developed and tested in a laboratory setting.

View Article and Find Full Text PDF