Effect of odor treatment systems on bioaerosol microbial concentration and diversity from wastewater treatment plants.

Sci Total Environ

Department of Civil, Geological and Mining Engineering, Polytechnique Montréal, Montréal, QC, Canada. Electronic address:

Published: May 2023

Biofiltration, activated carbon and chemical scrubbing are technologies used for odor control in wastewater treatment plants. These systems may also influence the airborne microbial load in treated air. The study objectives were to 1) evaluate the capacity of three odor control system technologies to reduce the airborne concentration of total bacteria, Legionella, L. pneumophila, non-tuberculous mycobacteria (NTM) and Cladosporium in winter and summer seasons and 2) to describe the microbial ecology of the biofiltration system and evaluate its impact on treated air microbial diversity. A reduction of the total bacterial concentration up to 25 times was observed after odor treatment. Quantification by qPCR revealed the presence of Legionella spp. in all air samples ranging between 26 and 1140 GC/m, while L. pneumophila was not detected except for three samples below the limit of quantification. A significant increase of up to 25-fold of Legionella spp. was noticed at the outlet of two of the three treatment systems. NTM were ubiquitously detected before air treatment (up to 2500 GC/m) and were significantly reduced by all 3 systems (up to 13-fold). Cladosporium was measured at low concentrations for each system (< 190 GC/m), with 68 % of the air samples below the limit of detection. Biodiversity results revealed that biofiltration system is an active process that adapts to air pollutants over time. Legionella spp. were detected in significant abundance in the air once treated in winter (up to 27 %). Nevertheless, the abundance of protozoan hosts is low and does not explain the multiplication of Legionella spp. The season remains the most influential factor shaping biodiversity. In summer only, air biofiltration caused a significant enrichment of the biodiversity. Although odor control technologies are not designed for bacterial mitigation, findings from this study suggest their potential to reduce the abundance of some genera harboring pathogenic species.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2023.162419DOI Listing

Publication Analysis

Top Keywords

legionella spp
16
odor control
12
odor treatment
8
treatment systems
8
wastewater treatment
8
treatment plants
8
air
8
treated air
8
biofiltration system
8
air samples
8

Similar Publications

Multiple human and plant pathogens are dispersed and transmitted as bioaerosols (e.g., , SARS-CoV-2, , , spp.

View Article and Find Full Text PDF

Aims: We investigated the combined effects of pipe materials and disinfection chemicals on bacterial community and its active RNA fraction in water and biofilms in a pilot-scale premise plumbing system.

Methods And Results: The changes in bacterial communities were studied within four pipelines using copper and cross-linked polyethylene (PEX) pipe with chlorine or chloramine disinfection. The total and active bacterial communities and the presence of opportunistic pathogens (Legionella spp.

View Article and Find Full Text PDF

Hot water systems are the most frequent environment associated with the prevalence and growth of opportunistic premise plumbing pathogens (OPPPs). Previous studies identified water heaters as a source of waterborne diseases and concluded that design variables may contribute to their prevalence. A multifaceted approach was used to investigate the vertical stratification of the microbiome and selected OPPPs in an electric water heater tank connected to a home plumbing system simulator.

View Article and Find Full Text PDF

Synergistic effects of ozonation pretreatment and trace phosphate on water quality health risk and microbial stability in simulated drinking water distribution systems.

J Hazard Mater

December 2024

Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou 510006, China.

The proliferation and chlorine resistance of pathogenic bacteria in drinking water distribution systems (DWDSs) pose a serious threat to human health. In this study, the synergistic effects of ozonation pretreatment and trace phosphate on water quality health risk and microbial stability were investigated in the small-scale DWDSs simulated by biofilms annular reactors with cast iron coupons. The results indicated that ozonation of drinking water containing trace phosphate was equivalent to increasing microbial carbon and phosphorus sources, further leading to the rapid proliferation of opportunistic pathogens (OPs) in subsequent DWDSs.

View Article and Find Full Text PDF

In June 2022, a 73-year-old man with a history of laryngeal and esophageal carcinoma was admitted to the emergency unit with sudden fever, confusion, and general condition deterioration. Initial assessments showed a fever of 38.5 °C, elevated C-reactive protein (CRP) at 209 mg/L, and a neutrophil count of 10.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!