Background: This study aimed to: (1) Determine the ability to achieve the surgeons' desired cup orientation, without navigation, using contemporary measures with the anterior- (AA) and posterior- approaches (PA); and (2) assess whether surgical approach is associated with cup orientation accuracy, as previously reported, when contemporary measures are used.
Methods: A prospective, 2-centre, multi-surgeon study of 400 THAs (200 AA; 200 PA) was performed. Intraoperative radiographs were obtained with the AA. A digital inclinometer and 3-point pelvic support were used with the PA. With the PA, intraoperative cup inclination at impaction was recorded. Radiographic inclination/anteversion (RI/RA) was measured from intraoperative radiographs (AA-only) and from postoperative radiographs for all cases. Optimum inclination/anteversion was defined as 40°/20° (±10°). The difference between intra- and postoperative orientations allowed for determination of the difference in pelvic position at impaction.
Results: Optimum RI and RA were achieved in 91.3% ( = 365) and 92% ( = 368) of cases respectively. Optimum cup orientation was detected in 84% of cases ( = 336). There was equivalent ability to achieve cup orientation between approaches (AA: 82.5% vs. PA: 85.5%; = 0.41). The use of an inclinometer in the PA was associated with a smaller variability of inclination at implantation (10° vs. 14°) and counteracted the greater difference in pelvic position (4.4° vs. 2.1°) seen with the PA.
Conclusions: Over 80% of cases can have optimum orientation without navigation, using simple, cheap contemporary measures. Such measures eliminate differences between approaches, related to patient position. Narrower implantation angles will further reduce variability in cup orientation achieved.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/11207000231156543 | DOI Listing |
Hip Int
January 2025
Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.
Background: Different methods can help to optimise sagittal cup orientation in total hip arthroplasty (THA) based on individual spinopelvic characteristics. This study aimed to: (1) assess how often combined sagittal index (CSI) and hip-spine-classification targets were achieved post THA; (2) compare anteversion/inclination between cups in-/outside optimal CSI zone; and (3) determine association with outcome.
Methods: This is a multicentre, prospective, case-cohort study of 435 primary THA for osteoarthritis (53% females; age: 65 ± 12 years; follow-up: 2.
Surg Technol Int
January 2025
JIS Orthopedics Inc., New Albany, Ohio.
Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.
View Article and Find Full Text PDFArthroplasty
January 2025
Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy.
Background: Proper positioning of a total hip arthroplasty (THA) plays a crucial role in the success and long-term survivorship of the implant. Cup positioning within the Lewinnek Safe Zone (LSZ) does not, however, avoid implant dislocation. Thus, the concept of a functional cup position has been introduced.
View Article and Find Full Text PDFBone Jt Open
January 2025
Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Japan.
Aims: Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system.
Methods: We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan.
SICOT J
December 2024
The Hazeley Academy, Emperor Drive, Hazeley, Milton Keynes, MK8 0PT, United Kingdom.
Introduction: Robot-assisted instrumentation during total hip arthroplasty (THA) has the potential to improve acetabular cup positioning. This study aimed to evaluate the precision of robotic-arm-assisted THA (rTHA) and assess whether the system can provide accurate cup positioning comparable to conventional THA (cTHA).
Methods: A single-center prospective cohort study consisting of 151 patients who underwent THA (108 rTHA and 43 cTHA).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!