Objective: To compare Pediatric Advanced Life Support (PALS) diastolic blood pressure (DBP) criteria to empirically derived DBP criteria for the prediction of out-of-hospital interventions in children.

Methods: We performed a retrospective study of pediatric (<18 years) encounters from the ESO Data Collaborative, which includes approximately 2000 Emergency Medical Services agencies in the United States. We developed age-based centile curves for DBP using generalized additive models for location, scale, and shape. We compared the proportion of encounters with a low DBP when using empirically derived and PALS criteria and calculated their associations with the delivery of out-of-hospital interventions (advanced airway management, cardiopulmonary resuscitation, cardiac epinephrine, any systemic epinephrine, defibrillation, and bolus intravenous fluids).

Results: We included 343,129 encounters. When using PALS criteria, 155,564 (45.3%) were classified as having  abnormal DBP, including 120,624 (35.2%) with high DBP and 34,940 (10.2%) with low DBP. When using empirically-derived criteria, 18.6% had an abnormal DBP (ie, a DBP <10th or >90th centile). The accuracy of low DBP for out-of-hospital interventions between the two criteria was similar.

Conclusion: PALS criteria for DBP classified a high proportion of children as having abnormal vital signs, particularly with diastolic hypertension. Empirically derived DBP thresholds more accurately predict the delivery of key out-of-hospital interventions. If externally validated, correlated to in-hospital outcomes, and combined with thresholds for other vital signs, these may better predict the need for out-of-hospital interventions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958513PMC
http://dx.doi.org/10.1002/emp2.12915DOI Listing

Publication Analysis

Top Keywords

diastolic blood
8
blood pressure
8
dbp criteria
8
age-based centiles
4
centiles diastolic
4
pressure children
4
children out-of-hospital
4
out-of-hospital emergency
4
emergency setting
4
setting objective
4

Similar Publications

Background: Maternal hemoglobin (Hb) is related to nutritional status, and it widely fluctuates during pregnancy. However, the relationship between Hb and blood pressure (BP) during pregnancy is unclear. This study aimed to estimate the associations between maternal Hb in various trimesters and its changes with BP during pregnancy.

View Article and Find Full Text PDF

Background: Plant-based foods have reduced protein digestibility and frequently display unbalanced amino acid profiles. Plant-based foods are therefore considered inferior to animal-based foods in their anabolic potential. No study has assessed the anabolic potential of a vegan diet that provides a large variety of plant-based protein sources in older adults.

View Article and Find Full Text PDF

Introduction: The aim of the observational SIMPLE study was to assess real-life effectiveness and safety of a single-pill combination (SPC) of perindopril arginine/amlodipine in a broad range of subjects with newly diagnosed mild-to-moderate hypertension treated in Canadian general practice.

Methods: Treatment-naïve participants aged 18-65 years with mild-to-moderate hypertension, whose physicians decided to initiate the perindopril/amlodipine SPC, were recruited from Canadian clinical practice from October 2017 to February 2019. Participants were followed at 3- (M3) and 6-month (M6) visits after treatment initiation.

View Article and Find Full Text PDF

Background: Self-reported mental stress is not consistently recognized as a risk factor for stroke. This prompted development of a novel algorithm for stress-phenotype indices to quantify chronic stress prevalence in relation to a modified stroke risk score in a South African cohort. The algorithm is based on biomarkers adrenocorticotrophic hormone, high-density lipoprotein cholesterol, high-sensitive cardiac-troponin-T, and diastolic blood pressure which exemplifies the stress-ischemic-phenotype index.

View Article and Find Full Text PDF

Development of a Self-Deploying Extra-Aortic Compression Device for Medium-Term Hemodynamic Stabilization: A Feasibility Study.

Adv Sci (Weinh)

December 2024

Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE), UNSW Sydney, Kensington Campus, Sydney, NSW, 2052, Australia.

Hemodynamic stabilization is crucial in managing acute cardiac events, where compromised blood flow can lead to severe complications and increased mortality. Conditions like decompensated heart failure (HF) and cardiogenic shock require rapid and effective hemodynamic support. Current mechanical assistive devices, such as intra-aortic balloon pumps (IABP) and extracorporeal membrane oxygenation (ECMO), offer temporary stabilization but are limited to short-term use due to risks associated with prolonged blood contact.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!