Fabry-Perot laser diodes based on (Al, Ga)As and Ga(As, Bi) with single or multiple parabolic or rectangular-shaped quantum wells (QWs) emitting at the 780-1100 nm spectral range were fabricated and investigated for optimization of the laser QW design and composition of QWs. The laser structures were grown using the molecular beam epitaxy (MBE) technique on the -type GaAs(100) substrate. The photolithography process was performed to fabricate edge-emitting laser bars of 5 μm by 500 μm in size. The temperature-dependent power-current measurements showed that the characteristic threshold current of the fabricated LDs was in the 60-120 mA range. Light and current characteristics were almost linear up to (1.2-2.0) . Low-frequency 10 Hz-20 kHz electrical and optical noise characteristics were measured in the temperature range from 70 K to 290 K and showed that the low-frequency optical and electrical noise spectra are comprised of 1/ and Lorentzian-type components. The positive cross-correlation between optical and electrical fluctuations was observed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9965910 | PMC |
http://dx.doi.org/10.3390/s23042282 | DOI Listing |
J Acoust Soc Am
January 2025
Applied Health Research (TGO), University Medical Center Groningen (UMCG), Groningen, the Netherlands.
Low frequency noise (LFN) of unknown origin can be disturbing, especially at night, and affect sleep and relaxation. If reduction of the LFN is impossible, adding sound can mask the troubling noise or detract attention from it to reduce distress. To assess the effectiveness of this, a survey was set up consisting of three questionnaires: the first when a person requested a masking sound and follow-ups after 1 and 3 months.
View Article and Find Full Text PDFAnal Chem
January 2025
Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-41061, United States.
Glow discharge optical emission spectrometry (GDOES) allows fast and simultaneous multielemental analysis directly from solids and depth profiling down to the nanometer scale, which is critical for thin-film (TF) characterization. Nevertheless, operating conditions for the best limits of detection (LODs) are compromised in lieu of the best sputtering crater shapes for depth resolution. In addition, the fast transient signals from ultra-TFs do not permit the optimal sampling statistics of bulk analysis such that LODs are further compromised.
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.
Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.
Study Type: Prospective.
J Neuroeng Rehabil
January 2025
Dept. of Cognitive Robotics, TU Delft, Delft, Netherlands.
Background: Head-mounted displays can be used to offer personalized immersive virtual reality (IVR) training for patients who have suffered an Acquired Brain Injury (ABI) by tailoring the complexity of visual and auditory stimuli to the patient's cognitive capabilities. However, it is still an open question how these virtual environments should be designed.
Methods: We used a human-centered design approach to help define the characteristics of suitable virtual training environments for ABI patients.
Inf inference
March 2025
Program in Applied Mathematics, Yale University, New Haven, CT 06520, US.
Detecting and recovering a low-rank signal in a noisy data matrix is a fundamental task in data analysis. Typically, this task is addressed by inspecting and manipulating the spectrum of the observed data, e.g.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!