Background: The objective of this study was to compare the clinical efficacy of Resin modified glass ionomer cement and Flowable composite in terms of retention, marginal adaptation and surface texture using United States Public Health Service criteria in non-carious cervical lesions measured over a period of one year.

Methods: A Randomized Clinical Trial is conducted with Informed consent on 60 patients who are randomly allocated into 2 groups with at least 2 Non Carious Cervical Lesions in each. Group 1 is used for Flowable Composite while group 2 is used for resin modified glass ionomer cement. A recall is maintained to draw conclusions between two materials in terms of occurrence of marginal adaptation, retention and surface texture, to show which material is superior to other.

Results: Out of 30 restorations in 12 months follow up, only 19 found to be present in flowable composite group while in resin modified glass ionomer cement group, 28 are retained. Regarding margin integrity, Group 1 showed 21 intact margins whereas 23 margins were intact in group 2, while 18 and 25 showed smooth surface in flowable composite and Resin modified glass ionomer cement group respectively, on exploration.

Conclusion: It can be concluded from our study that Resin modified glass ionomer cement is superior to Flowable composite in terms of retention (p=0.005) and surface texture (p=0.045) in restoration of non carious cervical lesion.

Download full-text PDF

Source
http://dx.doi.org/10.55519/JAMC-01-10780DOI Listing

Publication Analysis

Top Keywords

resin modified
24
modified glass
24
glass ionomer
24
ionomer cement
24
flowable composite
20
cervical lesions
12
surface texture
12
clinical efficacy
8
efficacy resin
8
cement flowable
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!