Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In this study, an immunochromatographic test (using the Charm QUAD2® Test) was used to screen for residual macrolides and lincosamides in raw cow's milk. The validation parameters (selectivity/specificity, detection capability (CCβ), and ruggedness) were in agreement with the requirements of[EC] 2021. The selectivity of the immunochromatographic test was verified by the negative results of microbiological tests. The false-positive rate was 0%. The CCβ values of the immunochromatographic test for various antibiotics in milk were as follows: erythromycin 0.02 mg/kg, spiramycin 0.1 mg/kg, tilmicosin 0.025 mg/kg, tylosin 0.05 mg/kg, lincomycin 0.15 mg/kg, and pirlimycin 0.15 mg/kg. The determined CCβ values were lower than the respective maximum residue limits (MRLs; regulatory limits in Japan) for milk, except for lincomycin (equal to the MRL). The presence of antibiotic groups other than macrolides and lincosamides did not interfere with the specificity of the test. It showed no significant difference in lot-to-lot repeatability. The results obtained by the two researchers showed no significant differences. Finally, the test was applied to milk samples obtained from a tylosin-treated cow. The outcome was positive and in agreement with the results of the chemical analytical and microbiological methods. Therefore, this validated immunochromatographic test is expected to be suitable for routine analysis to ensure milk safety.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/19440049.2023.2177504 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!