The development of triboelectric nanogenerators (TENGs) technology has advanced in recent years. However, TENG performance is affected by the screened-out surface charge density owing to the abundant free electrons and physical adhesion at the electrode-tribomaterial interface. Furthermore, the demand for flexible and soft electrodes is higher than that for stiff electrodes for patchable nanogenerators. This study introduces a chemically cross-linked (XL) graphene-based electrode with a silicone elastomer using hydrolyzed 3-aminopropylenetriethoxysilanes. The conductive graphene-based multilayered electrode was successfully assembled on a modified silicone elastomer using a cheap and eco-friendly layer-by-layer assembly method. As a proof-of-concept, the droplet-driven TENG with the chemically XL electrode of silicone elastomer exhibited an output power of approximately 2-fold improvement owing to its higher surface charge density than without XL. This chemically XL electrode of silicone elastomer film demonstrated remarkable stability and resistance to repeated mechanical deformations like bending and stretching. Moreover, due to the chemical XL effects, it was used as a strain sensor to detect subtle motions and exhibited high sensitivity. Thus, this cheap, convenient, and sustainable design approach can provide a platform for future multifunctional wearable electronic devices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9948220 | PMC |
http://dx.doi.org/10.1021/acsomega.3c00008 | DOI Listing |
Adv Mater
January 2025
Department of Materials Science and Engineering, University of Pennsylvania, 3231 Walnut Street, Philadelphia, PA, 19104, USA.
Cholesteric liquid crystal elastomers (CLCEs) hold great promise for mechanochromic applications in anti-counterfeiting, smart textiles, and soft robotics, thanks to the structural color and elasticity. While CLCEs are printed via direct ink writing (DIW) to fabricate free-standing films, complex 3D structures are not fabricated due to the opposing rheological properties necessary for cholesteric alignment and multilayer stacking. Here, 3D CLCE structures are realized by utilizing coaxial DIW to print a CLC ink within a silicone ink.
View Article and Find Full Text PDFMicromachines (Basel)
December 2024
Department of Mechanical Engineering, Inha University, Incheon 22212, Republic of Korea.
The application of smart materials in robots has attracted considerable research attention. This study developed an inchworm robot that integrates smart materials and a bionic design, using the unique properties of magnetorheological elastomers (MREs) to improve the performance of robots in complex environments, as well as their adaptability and movement efficiency. This research stems from solving the problem of the insufficient adaptability of traditional bionic robots on different surfaces.
View Article and Find Full Text PDFBiosens Bioelectron
January 2025
Department of Physics, Virginia Commonwealth University, Richmond, VA, 23284, USA; Institute for Sustainable Energy and Environment, Virginia Commonwealth University, Richmond, VA, 23284, USA. Electronic address:
Wearable devices designed for the somatosensory system aim to provide event-cue feedback electronics and therapeutic stimulation to the peripheral nervous system. This prompts a neurological response that is relayed back to the central nervous system. Unlike virtual reality tools, these devices precisely target peripheral mechanoreceptors by administering specific stimuli.
View Article and Find Full Text PDFNat Commun
January 2025
Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan, China.
Inspired by counterintuitive water "swelling" ability of the hydrophobic moss of the genus Sphagnum (Peat moss), we prepared a hydrophobic pseudo-hydrogel (HPH), composed of a pure hydrophobic silicone elastomer with a tailored porous structure. In contrast to conventional hydrogels, HPH achieves absorption-induced volume expansion through surface tension induced elastocapillarity, presenting an unexpected absorption-induced volume expansion capability in hydrophobic matrices. We adopt a theoretical framework elucidating the interplay of surface tension induced elastocapillarity, providing insights into the absorption-induced volume expansion behavior.
View Article and Find Full Text PDFMed Sci Monit
January 2025
Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
BACKGROUND A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in short-span and long-span fixed partial dentures (FPD). MATERIAL AND METHODS A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!