Objectives: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions.

Background: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications.

Methods: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1-year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events.

Results: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per-protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One-year follow-up outcomes were comparable.

Conclusions: Treatment of calcified lesions with high-pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.30603DOI Listing

Publication Analysis

Top Keywords

cutting balloon
8
inflated high
8
high pressure
8
treatment calcified
8
calcified lesions
8
device failure
8
compared ncb
8
level calcium
8
calcium site
8
higher eccentricity
8

Similar Publications

Article Synopsis
  • Heavily calcified coronary artery disease complicates percutaneous coronary intervention (PCI), requiring advanced techniques like cutting balloons (CB), which need standardization for better effectiveness.
  • The study presents the RODIN-CUT technique, which involves sequential CB inflations guided by intravascular ultrasound (IVUS) to improve plaque modification and stent expansion in difficult cases.
  • Results indicate that RODIN-CUT achieved high procedural success rates and minimal complications, suggesting it could be a simple and cost-effective method for treating calcified lesions, though larger studies are needed to confirm its validity.
View Article and Find Full Text PDF

Recent Advances in the Treatment of Coronary In-Stent Restenosis.

Rev Cardiovasc Med

December 2024

Department of Cardiology, Bern University Hospital, Inselspital, CH-3010 Bern, Switzerland.

In-stent restenosis (ISR) remains the predominant cause of stent failure and the most common indication for repeat revascularization. Despite technological advances in stent design, ISR continues to pose significant challenges, contributing to increased morbidity and mortality among patients undergoing percutaneous coronary interventions. In the last decade, intravascular imaging has emerged as an important method for identifying the mechanisms behind ISR and guiding its treatment.

View Article and Find Full Text PDF

A high recurrence rate is undesirable after treatment of common bile duct (CBD) stones. A major risk factor identified for recurrence is that invasive techniques, including surgical or endoscopic treatments, will impair the biliary tract system either by direct incision of the CBD or by cutting or dilating the ampulla of Vater. During endoscopic treatment, two main assisted methods for lithotomy, sphincterotomy and papillary balloon dilation, can result in different degrees of damage to the structure and function of the sphincter of Oddi (SO), contributing to slowing of biliary excretion, cholestasis, biliary bacterial infection, and promotion of bile duct stone recurrence.

View Article and Find Full Text PDF

Steroid-resistant immunoglobulin G4-related coronary arteritis: a case report.

Eur Heart J Case Rep

October 2024

Department of Cardiology, Kagawa Prefectural Central Hospital, 1-2-1 Asahi-machi, Takamatsu City, Kagawa 760-8557, Japan.

Background: Immunoglobulin G4 (IgG4)-related diseases are systemic fibroinflammatory disease characterized by extensive infiltration of IgG4-positive plasma cells in the affected tissue(s), with high plasma levels of IgG4. However, coronary involvement is rare.

Case Summary: A 70-year-old man was diagnosed with IgG4-related coronary arteritis, pancreatitis, and cholangitis during full-body contrast computed tomography (CT) examination prior to surgery for an iliac artery aneurysm.

View Article and Find Full Text PDF

Background: Rotational atherectomy (RA) has been proven to treat coronary artery calcification (CAC) during percutaneous coronary intervention (PCI).

Purpose: This study evaluates the safety and efficacy of RA followed by cutting balloon angioplasty (ROTACUT) before stent placement in CAC.

Methods: A systematic review and meta-analysis of randomized controlled trials and observational studies was conducted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!