Objectives: Twin pregnancies complicated by twin-twin transfusion syndrome (TTTS) are at particularly high risk of preterm birth. Cervical length (CL) measurement on transvaginal ultrasound (TVS) is a powerful predictor of preterm birth, but the predictive accuracy of CL measurement on magnetic resonance imaging (MRI) has not yet been established. We sought to investigate the correlation between CL measurements obtained on preoperative TVS and on MRI and to quantify their predictive accuracy for preterm birth among pregnancies complicated by TTTS that underwent selective fetoscopic laser photocoagulation (SFLP), to identify whether MRI is a useful adjunct to TVS.
Methods: This was a retrospective cohort study of pregnancies that were treated for TTTS with SFLP at a single center between April 2010 and June 2019 and that underwent TVS and MRI evaluation. Correlation was estimated using Pearson's coefficient, mean CL measurements were compared using the two-tailed paired t-test and the frequency at which a short cervix was detected by the two imaging modalities was compared using the χ-square test. Generalized linear models were used to estimate relative risk and receiver-operating-characteristics (ROC)-curve analysis was used to estimate the predictive accuracy of CL for preterm birth.
Results: Among 626 pregnancies complicated by TTTS that underwent SFLP, CL measurements were obtained on preoperative TVS in 579 cases and on preoperative MRI in 434. CL ≤ 2.5 cm was recorded in 39 (6.7%) patients on TVS and 47 (10.8%) patients on MRI (P = 0.0001). Measurements of CL made on MRI correlated well with those obtained on TVS overall (r = 0.63), but correlation was weak at the shortest CLs (r < 0.20). MRI failed to detect two (40.0%), three (18.8%), nine (32.1%) and 13 (28.9%) cases diagnosed as having a short cervix on TVS at cut-offs of ≤ 1.5 cm, ≤ 2.0 cm, ≤ 2.5 cm and ≤ 2.8 cm, respectively. Over half of the pregnancies with a preoperative CL of ≤ 2.5 cm delivered by 28 weeks' gestation, regardless of imaging modality. CL measurement on TVS was superior to that on MRI to predict preterm birth, the latter performing poorly at all CL cut-offs. A CL measurement of ≤ 2.0 cm on preoperative TVS had the highest predictive ability for preterm birth, with an area under the ROC curve for delivery before 32 weeks of 0.82.
Conclusions: Although measurement of CL on MRI correlates well with that on TVS overall, it performs poorly at accurately detecting a short cervix. TVS outperforms MRI in evaluation of the cervix and remains the optimal modality for CL measurement in pregnancies at high risk for preterm birth, such as those undergoing SFLP for TTTS. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/uog.26184 | DOI Listing |
Matern Child Health J
January 2025
Department of Obstetrics and Gynecology, The University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
Objectives: In cases of preterm delivery, the Medicaid sterilization policy mandates a signed consent form at least 72 h before surgery for permanent contraception, which is less than the 30 day minimum waiting period for term births. This study evaluated the association between preterm birth and fulfillment of planned permanent contraception.
Study Design: This was a secondary analysis of a multi-center retrospective cohort study of 3013 patients with a postpartum contraceptive plan of permanent contraception.
Qual Manag Health Care
January 2025
Philip R. Lee Institute for Health Policy Studies, University of California San Francisco, San Francisco, CA.
Front Endocrinol (Lausanne)
January 2025
Center for Reproductive Medicine and Obstetrics and Gynecology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
Background: Thin endometrial thickness (EMT) and advanced age are both common risk factors for adverse neonatal outcomes (ANOs). However, studies evaluating the impact of EMT and combined effect of EMT and age on ANOs remain scarce with conflicts.
Method: A retrospective cohort study was conducted on 7,715 singleton deliveries from frozen embryo transfer (FET) cycles between 2017 and 2021.
J Endocr Soc
January 2025
Department of Population and Public Health Sciences, Keck School of Medicine, University of Southern California, Los Angeles, CA 90032, USA.
Context: Worldwide, obesity remains one of the most challenging crises with children being one of the most susceptible populations. The effect of maternal stress during pregnancy on newborn body composition, measured by fat mass and lean mass has, not been extensively studied.
Objectives: We evaluated the association between perceived stress during late pregnancy and infant adiposity at 1 month and assessed effect modification by infant sex and preterm birth.
BMC Med
January 2025
Public Health Foundation of India, New Delhi, India.
Background: We synthesised the current evidence in coverage and quality of delivery care, change in neonatal mortality (NMR), and causes of neonatal death in the private sector deliveries in the Indian state of Bihar from 2011 to 2021.
Methods: Women aged 15-49 years with livebirths were interviewed in three household surveys involving state-representative samples in 2011, 2016 and 2020-2021 designed to document the coverage of maternal and newborn health services and change in NMR over time. Verbal autopsy interviews were used to assign the cause of neonatal death.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!