AI Article Synopsis

  • - Fetal surgery for myelomeningocele can reduce the risk of hydrocephalus by about 50%, prompting the need for training in a new endoscopic repair technique using multi-portals.
  • - The study developed a training model in two stages: first, familiarizing surgeons with 2D endoscopic skills and then applying these skills to simulate myelomeningocele closure using chicken breast and basketball models.
  • - The training involved testing two setups: a three-portal system allowing bimanual maneuvers for more complex procedures, and a two-portal system where the surgeon and assistant work side by side, with limited bi-manual capabilities.

Article Abstract

Purpose: The recent history of myelomeningocele has shown that treatment during the fetal life may reduce the risk of developing hydrocephalus in individuals by approximately 50%. Thus, a significant advancement involves fetal surgery performed through an endoscopic technique in which portals are placed to introduce the forceps and laparoscopic instruments. However, the development of this technique requires training; therefore, this study aimed to develop a training model for fetal myelomeningocele repair technique with multi-portal endoscopy.

Methods: Two stages of endoscopic technique development were performed. The first stage consisted of exercises in order to familiarize the surgeon with 2D-vision endoscopic surgery, associated with the application of exercises focused on surgical skills, such as the development of laparoscopic knots in a synthetic model. The second stage involved the creation and application of the stages of myelomeningocele closure with a non-living animal model consisting of a chicken breast to simulate the myelomeningocele and a basketball to simulate the gravid uterus, in which perforations were made to introduce vascular introducers (portals) that, as in vivo, are used as portals (trocars) for the introduction of laparoscopic instruments. Overall, two different scenarios with three portals and two portals were tested.

Results: In three-portal simulator, the triangular apex trocar was used for the introduction of 4-mm 0° or 30° optics or even Minop type neurodoscope (Aesculap®, Germany) that was operated by the assistant surgeon; the other two portals are used for the introduction of laparoscopic instruments. Thus, the surgeon is able to perform maneuvers bimanually since dissection to laparoscopic sutures. In two-portal simulator, the surgeon and assistant stay side by side and one of the portals is used for the optic and the other for the laparoscopic instruments. There is no possibility of bimanual dissection in this method.

Conclusion: Realistic simulation models for endoscopic fetal surgery for myelomeningocele correction are easily performed and help develop the necessary skills for fetal surgery teams.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00381-023-05893-5DOI Listing

Publication Analysis

Top Keywords

laparoscopic instruments
16
endoscopic technique
12
fetal surgery
12
training model
8
model fetal
8
fetal myelomeningocele
8
myelomeningocele correction
8
introduction laparoscopic
8
portals
7
fetal
6

Similar Publications

The surgical management of hepatic metastases from colorectal cancer may range from segmental resections to major or extended hepatectomies. The aim is to achieve complete removal of metastatic lesions while preserving adequate liver function. We present the case of a 42-year-old male patient with a history of glucose intolerance who presented with altered bowel movements and abdominal pain.

View Article and Find Full Text PDF

Surgeons in training have a limited opportunity to practice their skills in a realistic surgical environment. Surgical training models are expensive and are often single-use exercises involving consumable supplies. The goal of the work presented in this paper is to increase surgeon training time by developing a surgical training simulator that is portable, inexpensive, and offers a realistic surgical environment.

View Article and Find Full Text PDF

Total laparoscopic closed reduction and internal fixation for AO/OTA B2.1 pelvic fracture: A case report and literature review.

Chin J Traumatol

December 2024

Division of Trauma and War Injury, Daping Hospital, Army Medical University of PLA, Chongqing, 400042, China. Electronic address:

Endoscopic techniques have been widely used in orthopedic surgery, such as arthroscopy and transforaminal endoscopy, but the application in fracture is rarely reported. We reported a case of a 69-year-old male with pelvic fracture (AO/OTA type B2.1) who underwent successful laparoscopy-assisted pubic ramus plate fixation without auxiliary incision.

View Article and Find Full Text PDF

Improved surgical skill is generally associated with improved patient outcomes, although assessment is subjective, labour intensive, and requires domain-specific expertise. Automated data-driven metrics can alleviate these difficulties, as demonstrated by existing machine learning instrument tracking models. However, these models are tested on limited datasets of laparoscopic surgery, with a focus on isolated tasks and robotic surgery.

View Article and Find Full Text PDF

Despite the benefits of minimally invasive surgery, interventions such as laparoscopic liver surgery present unique challenges, like the significant anatomical differences between preoperative images and intraoperative scenes due to pneumoperitoneum, patient pose, and organ manipulation by surgical instruments. To address these challenges, a method for intraoperative three-dimensional reconstruction of the surgical scene, including vessels and tumors, without altering the surgical workflow, is proposed. The technique combines neural radiance field reconstructions from tracked laparoscopic videos with ultrasound three-dimensional compounding.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!