A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Carbon Dots-Based Fluorescence Assay for the Facile and Reliable Detection of Ag in Natural Water and Serum Samples. | LitMetric

Carbon Dots-Based Fluorescence Assay for the Facile and Reliable Detection of Ag in Natural Water and Serum Samples.

Molecules

Yunnan Key Laboratory for Micro/Nano Materials & Technology, School of Materials and Energy, Yunnan University, Kunming 650091, China.

Published: February 2023

In this report, red-emissive carbon dots (C-dots) were facilely prepared from -phenylenediamine via microwave-assisted hydrothermal treatment. The C-dots demonstrated excitation wavelength-independent emission with maximums at 621 nm that could be effectively quenched by Ag via static quenching. This phenomenon was exploited to establish a sensitive fluorescence assay with a low detection limit (0.37 μM) and wide linear range (0-50 μM). In addition, this assay demonstrated excellent selectivity toward Ag, free from the interference of 16 commonly seen metal ions. Most importantly, the assay demonstrated high reliability toward samples in deionized water, mineral water, lake water, and serum, which could indicate potential applications for Ag monitoring in complicated natural and biological environments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963176PMC
http://dx.doi.org/10.3390/molecules28041566DOI Listing

Publication Analysis

Top Keywords

fluorescence assay
8
water serum
8
assay demonstrated
8
carbon dots-based
4
dots-based fluorescence
4
assay
4
assay facile
4
facile reliable
4
reliable detection
4
detection natural
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!