A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Magnetic Anisotropies and Exchange Bias of Co/CoO Multilayers with Intermediate Ultrathin Pt Layers. | LitMetric

Co/CoO multilayers are fabricated by means of radio-frequency magnetron sputtering. For the formation of each multilayer period, a Co layer is initially produced followed by natural oxidation. Platinum is used not only as buffer and capping layers, but also in the form of intermediate ultrathin layers to enhance perpendicular magnetic anisotropy. Three samples are compared with respect to the magnetic anisotropies and exchange bias between 4-300 K based on superconducting quantum interference device magnetometry measurements. Two of the multilayers are identical Co/CoO/Pt ones; one of them, however, is grown on a Co/Pt "magnetic substrate" to induce perpendicular magnetic anisotropy via exchange coupling through an ultrathin Pt intermediate layer. The third multilayer is of the form Co/CoO/Co/Pt. The use of a "magnetic substrate" results in the observation of loops with large remanence when the field applies perpendicular to the film plane. The CoO/Co interfaces lead to a significant exchange bias at low temperatures after field cooling. The largest exchange bias was observed in the film with double Co/CoO/Co interfaces. Consequently, significant perpendicular anisotropy coexists with large exchange bias, especially at low temperatures. Such samples can be potentially useful for applications related to spintronics and magnetic storage.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963626PMC
http://dx.doi.org/10.3390/ma16041378DOI Listing

Publication Analysis

Top Keywords

exchange bias
20
magnetic anisotropies
8
anisotropies exchange
8
co/coo multilayers
8
intermediate ultrathin
8
ultrathin layers
8
perpendicular magnetic
8
magnetic anisotropy
8
"magnetic substrate"
8
bias low
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!