A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Graphene-Doped Polymethyl Methacrylate (PMMA) as a New Restorative Material in Implant-Prosthetics: In Vitro Analysis of Resistance to Mechanical Fatigue. | LitMetric

Background And Purpose: Provisional prostheses in restorations over several implants with immediate loading in completely edentulous patients increase the risk of frequent structural fractures. An analysis was performed of the resistance to fracture of prosthetic structures with cantilevers using graphene-doped polymethyl methacrylate (PMMA) resins and CAD-CAM technology.

Methods: A master model was produced with four implants measuring 4 mm in diameter and spaced 3 mm apart, over which 44 specimens representing three-unit fixed partial prostheses with a cantilever measuring 11 mm were placed. These structures were cemented over titanium abutments using dual cure resin cement. Twenty-two of the 44 units were manufactured from machined PMMA discs, and 22 were manufactured from PMMA doped with graphene oxide nanoparticles (PMMA-G). All of the samples were tested in a chewing simulator with a load of 80 N until fracture or 240,000 load applications.

Results: The mean number of load applications required for temporary restoration until the fracture was 155,455 in the PMMA-G group versus 51,136 in the PMMA group.

Conclusions: Resistance to fracture under cyclic loading was three times greater in the PMMA-G group than in the PMMA group.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9960587PMC
http://dx.doi.org/10.3390/jcm12041269DOI Listing

Publication Analysis

Top Keywords

graphene-doped polymethyl
8
polymethyl methacrylate
8
methacrylate pmma
8
resistance fracture
8
pmma-g group
8
pmma
6
pmma restorative
4
restorative material
4
material implant-prosthetics
4
implant-prosthetics vitro
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!