Recently, the quest for novel glaucoma surgical techniques and devices has been underway. Trabeculectomy remains the gold standard, but it requires the implantation of glaucoma drainage devices and frequent follow-ups, and it also carries a high risk of serious complications. The need for less invasive and safer procedures has led to the development of minimally invasive glaucoma surgery (MIGS), particularly for patients with mild-to-moderate disease. Among them, minimally invasive bleb surgery seems to be effective in classical glaucoma surgery, while maintaining MIGS benefits. The relatively new PreserFlo MicroShunt (Santen, Osaka, Japan) is registered in Europe. It was released in 2019 for the treatment of patients with early-to-advanced open-angle glaucoma, where intraocular pressure (IOP) remains uncontrolled while on maximum tolerated medication and/or where glaucoma progression warrants surgery. This review focuses on the place of the PreserFlo MicroShunt, characterized by ab externo implantation, among MIGS procedures, discussing its advantages and disadvantages. The mechanisms of action, technical aspects, efficacy, and safety issues are summarized. The surgical technique, its efficacy, and safety profile are described, and directions for future studies are indicated. The PreserFlo MicroShunt ensures a high safety profile, minimal anatomical disruption, meaningful IOP-lowering effect, and ease of use for patients and physicians.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9957246PMC
http://dx.doi.org/10.3390/ijerph20042904DOI Listing

Publication Analysis

Top Keywords

preserflo microshunt
16
minimally invasive
12
glaucoma surgery
12
invasive glaucoma
8
efficacy safety
8
safety profile
8
glaucoma
7
surgery
5
preserflo
4
microshunt context
4

Similar Publications

Comparison of outcomes with and without intrastent placement during PMS surgery.

Sci Rep

January 2025

Department of Ophthalmology and Visual Science, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku City, 783-8505, Kochi, Japan.

To assess the efficacy of using a nylon suture as a stent in the PreserFlo MicroShunt (PMS) lumen to prevent postoperative hypotony, 59 eyes that underwent PMS implantation with follow-up for > 6 months were analyzed. Patients were divided into no intrastenting (NST) and intrastenting (ST) groups, with the ST group subdivided into 9 - 0 nylon suture fully placed (9 F), 9 - 0 nylon suture placement in only half of the lumen (9 H), 10 - 0 nylon suture fully placed (10 F), and 10 - 0 nylon suture placement in only half of the lumen (10 H). The distribution was as follows: 23 eyes in the NST group, 10 in the 9 F group, 9 in the 9 H group, 11 in the 10 F group, and 6 in the 10 H group.

View Article and Find Full Text PDF

Purpose: To assess the efficacy and safety of PreserFlo MicroShunt (PMS) combined with mitomycin C in patients with medically treated primary open-angle glaucoma (POAG).

Study Design: A retrospective observational study.

Methods: The study examined 83 eyes from 83 patients with medically treated glaucoma surgery naive POAG.

View Article and Find Full Text PDF

Background/ Aims: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (pRNFL) thickness using optical coherence tomography (OCT) after implantation of a PRESERFLO® microshunt for surgical glaucoma management in adult glaucoma patients.

Methods: Retrospective data analysis of 59 eyes of 59 participants undergoing implantation of a PRESERFLO microshunt between 2019 and 2022 at a tertiary center for glaucoma management. Surgical management included primary temporary occlusion of the glaucoma shunt to prevent early hypotony.

View Article and Find Full Text PDF

Xen 63 versus Preserflo MicroShunt implant in patients with primary open-angle glaucoma.

Sci Rep

January 2025

Department of Ophthalmology and ORL, Faculty of Medicine, Clinico San Carlos Hospital, Complutense University, Clinico San Carlos Hospital Health Research Institute (IdISSC), Calle del Prof Martín Lagos, s/n,, Madrid, 28040, Spain.

This study compared the efficacy safety profiles of the Xen 63 and Preserflo MicroShunt devices, both standalone, in patients with primary open-angle glaucoma (POAG). It is a retrospective and single-center study conducted on consecutive on patients with medically uncontrolled POAG who underwent either a standalone Xen 63 or a standalone Preserflo and had a 12-month follow-up visit. The primary outcome was the mean IOP at month-12.

View Article and Find Full Text PDF

Preserflo MicroShunt (PMS) implantation is a minimally invasive surgical procedure for treating glaucoma. Postoperative hypotony, a common complication of PMS implantation, can be prevented and treated with 10-0 nylon insertion. In this report, we present a case of postoperative hypotony following PMS implantation that was treated with intraluminal insertion of 9-0 nylon.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!