Aim: To evaluate and compare the clinical outcomes of Cention-N (CN) and stainless steel crowns (SSCs) as restorations for pulpotomised primary molars, and to study clinical and radiographic outcomes of pulpotomies restored with these materials.

Methods: The study was conducted on 60 pulpotomised molars with occlusoproximal caries. These were randomly divided into two groups and restored with either stainless steel crowns or Cention-N. Clinical performance of restorations and clinical and radiographic success of pulpotomy was examined at 6, 9 and 12 months.

Results: The mean scores for marginal integrity deteriorated significantly at 6, 9 and 12 months in both groups but in comparison were insignificant. The mean for proximal contact deteriorated significantly for the Cention-N group, whereas the mean for gingival health deteriorated remarkably for the stainless steel crown group at successive evaluations. No tooth in either group showed secondary caries or discomfort on biting, except for one tooth in Cention-N group which presented with secondary caries. The clinical success rate for pulpotomised molars was 100% for both groups until nine months, although this had reduced by the end of 12 months. Radiographically, the success rate was 79.3% for Cention-N, while it was 86.6% for stainless steel crowns at 12 months. There was no significant difference in clinical and radiographic success between either group.

Conclusion: Cention-N and stainless steel crowns are comparable for marginal integrity. However, crowns maintain significantly better proximal contacts while Cention-N was notably better for gingival health of the restored tooth. Both materials do not show secondary caries and discomfort on biting and are comparable in clinical and radiographic success of pulpotomy at the end of one year.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955046PMC
http://dx.doi.org/10.3390/children10020284DOI Listing

Publication Analysis

Top Keywords

stainless steel
20
steel crowns
16
clinical radiographic
16
radiographic success
12
secondary caries
12
clinical
8
cention-n stainless
8
pulpotomised molars
8
success pulpotomy
8
marginal integrity
8

Similar Publications

Inspired by the adhesion differences on the surfaces of fresh and dried rose petals, a rose bionic self-cleaning fog collector (RBSC) was designed and prepared to realize a self-driven fog harvesting function. The droplet detachment iteration rate was revealed by the regulating mechanism of the surface adhesion force of the RBSC and the influence of bionic texture parameters, as demonstrated through the fog harvesting experiment and droplet detachment failure analysis. Through the surface adhesion force regulation, the probability of droplet dissipation with the airflow is reduced by increasing the falling droplets' mass, and the single surface fog capture efficiency is up to 740 mg cm h.

View Article and Find Full Text PDF

Rapid detection of pork quality has garnered increasing attention due to its status as one of the most widely consumed meats in the world. This study developed an electrochemical impedance combined with sensory evaluation method to achieve real-time imaging and quality assessment of pork. The optimal parameters for pork detection were determined through system performance tests and a Design of Experiment, which included the use of an adjacent excitation pattern, an excitation current of 15 mA at 10 kHz, a detector diameter of 5 cm, and stainless-steel electrodes embedded in the pork.

View Article and Find Full Text PDF

AISI 316L stainless steel is extensively used in various fields, including medicine. In this study, in order to improve antibacterial properties, reduce elastic modulus, increase hydrophilicity and delay corrosion on the surface of AISI 316L stainless steel pieces for biomedical applications, zinc and magnesium elements were used for coating. Zn monolayer, Zn-Mg bilayer, and Zn-Mg-Zn triple coatings were deposited on AISI 316L substrates using the thermal evaporation method.

View Article and Find Full Text PDF

Introduction: Post-operative complications related to hardware, particularly symptoms caused by it, such as implant impingement, wire breakage, and skin infection are frequently reported following surgical management of patellar fractures with stainless steel wires. As a potential solution, some researchers have advocated for the use of non-absorbable sutures for fracture fixation. This study aims to investigate the clinical and radiological outcomes of patients treated with fiber taping as an alternative technique.

View Article and Find Full Text PDF

Electrochemical Detection of Hydrogen Peroxide at High Concentrations Using Hastelloy G35 Electrode.

Langmuir

January 2025

State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, P R China.

The detection of hydrogen peroxide (HO) at elevated concentrations while eliminating oxygen interference presents a significant challenge. Nickel-based stainless steel, such as Hastelloy G35, has shown excellent corrosion resistance. However, it has never been used in electroanalysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!