A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multicenter Testing of a Simple Molecular Diagnostic System for the Diagnosis of Mycobacterium Tuberculosis. | LitMetric

Multicenter Testing of a Simple Molecular Diagnostic System for the Diagnosis of Mycobacterium Tuberculosis.

Biosensors (Basel)

Department of Biotechnology, College of Life Science and Biotechnology, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea.

Published: February 2023

(MTB) is a communicable disease and still remains a threat to common health. Thus, early diagnosis and treatment are required to prevent the spread of infection. Despite the recent advances in molecular diagnostic systems, the commonly used MTB diagnostic tools are laboratory-based assays, such as mycobacterial culture, MTB PCR, and Xpert MTB/RIF. To address this limitation, point-of-care testing (POCT)-based molecular diagnostic technologies capable of sensitive and accurate detection even in environments with limited sources are needed. In this study, we propose simple tuberculosis (TB) molecular diagnostic assay by combining sample preparation and DNA-detection steps. The sample preparation is performed using a syringe filter with amine-functionalized diatomaceous earth and homobifunctional imidoester. Subsequently, the target DNA is detected by quantitative PCR (polymerase chain reaction). The results can be obtained within 2 h from samples with large volumes, without any additional instruments. The limit of detection of this system is 10 times higher than those of conventional PCR assays. We validated the clinical utility of the proposed method in 88 sputum samples obtained from four hospitals in the Republic of Korea. Overall, the sensitivity of this system was superior to those of other assays. Therefore, the proposed system can be useful for MTB diagnosis in limited-resource settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9954000PMC
http://dx.doi.org/10.3390/bios13020259DOI Listing

Publication Analysis

Top Keywords

molecular diagnostic
16
sample preparation
8
diagnostic
5
multicenter testing
4
testing simple
4
molecular
4
simple molecular
4
system
4
diagnostic system
4
system diagnosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!