Purpose: Dialysis patients have a different response than the non-dialysis population to infection with COVID-19. This study evaluates the prevalence of infection and lethality in patients receiving hemodialysis or peritoneal dialysis in Panama, compared to non-dialysis adult population, and reports of adverse events of vaccination.

Methods: This is a prospective, multi-center cohort study of spatients aged 18 years or older and receiving in-center hemodialysis or ambulatory peritoneal dialysis in 13 centers in Panama from March 2021 to 2022. For comparison with general population, the study used an extended period of two years.

Results: A total of 1531 patients receiving dialysis treatment accepted to participate. PD patients represented an 18% of study patients. Lethality was higher in peritoneal dialysis patients with COVID-19 infection than in hemodialysis in the study group (p 0.02). Total deaths in dialysis patients for 2020 were 156 patients, before vaccination; 79 in 2021; and 25 for the first trimester of 2022. Lethality for the period of 2020-2022 was 9.3% for dialysis patients and 0.2% for non-dialysis population. There was no difference in symptoms in first dose, but with second dose, hemodialysis patients reported fewer symptoms than peritoneal dialysis patients (p < 0.0001).

Conclusion: Ninety one percent of people in the country received BNT162b2 Pfizer BionTech vaccine. Lethality decreased from 30 to 5% once vaccination was available. There were no severe adverse effects and symptoms reported were less frequent than in general population, probably due to low reactogenicity in dialysis patients, or better tolerance to pain.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955520PMC
http://dx.doi.org/10.1007/s11255-023-03529-wDOI Listing

Publication Analysis

Top Keywords

peritoneal dialysis
20
dialysis patients
20
patients
11
dialysis
9
hemodialysis peritoneal
8
non-dialysis adult
8
adult population
8
non-dialysis population
8
patients receiving
8
study
6

Similar Publications

For patients undergoing long-term peritoneal dialysis (PD), exposure to biologically incompatible PD solutions and the consequent peritoneal structure change can lead to progressive angiogenesis and fibrosis, and ultimately result in ultrafiltration failure (UFF). Peritoneal transport studies in aquaporin 1 (AQP1) knockout mice indicate that water transport across the peritoneum is mediated by AQP1, which accounts for up to 50% of ultrafiltration. Another recent study on a large cohort of PD patients with kidney failure further substantiated the impact of AQP1 genotype variation on water channel expression in the peritoneal membrane, influencing water transport, ultrafiltration, and patient prognosis.

View Article and Find Full Text PDF

Peritoneal dialysis (PD) is a commonly used modality for kidney replacement therapy for patients with end-stage kidney disease (ESKD). PD offers many benefits, including home-based care, greater flexibility, and preservation of residual kidney function compared to in-center hemodialysis. Nonetheless, patients undergoing PD often face significant challenges, including systemic inflammation, PD-related peritonitis, metabolic disorders, and cardiovascular issues that can negatively affect their quality of life and treatment outcomes.

View Article and Find Full Text PDF

Background: The prevalence of chronic kidney disease (CKD) is increasing, reflecting the rising incidence of chronic diseases. With the continuous growth of the global geriatric population, a significant portion of individuals with CKD consists of those aged over 65. Regardless of the chosen treatment method, protein-energy loss in patients undergoing renal replacement therapy (RRT) has been associated with elevated morbidity and mortality rates.

View Article and Find Full Text PDF

A 46-year-old woman on peritoneal dialysis (PD) had cloudy peritoneal dialysis effluent that had persisted for 10 days by the time she visited our hospital. The white blood cell count in the effluent was elevated to 1500/μL, leading to a diagnosis of peritoneal dialysis-associated peritonitis. The effluent cleared within two days with treatment using cefazolin and ceftazidime, and the white blood cell count dropped to 0/μL by day 6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!