Statement Of Problem: Intraoral scanners (IOSs) provide a digital alternative to conventional implant impression techniques. However, the effect of the supramucosal height of the scan body and implant angulation on the accuracy of IOSs remains unclear.
Purpose: The purpose of this in vitro study was to measure the impact of the supramucosal height of the scan body and implant angulation on the accuracy (trueness and precision) of intraoral digital implant scans in partially edentulous models.
Material And Methods: Two maxillary partially edentulous casts with 4 implant analogs were fabricated, 1 with 4 parallel implants (P-groups) and 1 with 2 implants distally inclined 18 degrees (A-groups). An implant scan body was positioned on each implant analog (CARES RC Mono Scanbody). For each cast, 3 subgroups were determined based on the soft tissue moulage fabricated for each reference cast exposing 3 mm (P-3 and A-3 subgroups), 5 mm (P-5 and A-5 subgroups), and 7 mm (P-7 and A-7 subgroups) of the implant scan bodies. The 2 reference casts were registered by using a coordinate measurement machine and desktop scanner (7 Series Dental Wings) and then scanned using an IOS (TRIOS 4) (n=15). Linear and angular discrepancy values and root mean square (RMS) error values between the implant scan bodies measured on the reference and experimental scans were computed with an inspection software program (Geomagic). Mann-Whitney U tests with Bonferroni correction were applied for planned comparisons (α=.05/9 ≈ .006).
Results: For linear discrepancies, statistically significant differences were found between groups P-3 and A-3 (P=.004) and between P-7 and A-7 (P=.005). For angular discrepancies, statistically significant differences were found between groups A-3 and A-5 (P=.002) and between P-7 and A-7 (P=.003). The RMS error analysis found no statistically significant differences among the groups.
Conclusions: Implant angulation of 18 degrees did not significantly affect the accuracy of the intraoral scans in terms of 6 of the 9 planned comparisons, although the angled groups had lower mean values. Also, the supramucosal height of the scan body did not significantly affect the accuracy of the intraoral scans in terms of 17 of the 18 planned comparisons. Results may vary with different implant scan body designs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2023.01.018 | DOI Listing |
Eur J Emerg Med
September 2024
Department of Anaesthesiology and Intensive Care Medicine.
Background: Noncompressible truncal hemorrhage is a major contributor to preventable deaths in trauma patients and, despite advances in emergency care, still poses a big challenge.
Objectives: This study aimed to assess the clinical efficacy of trauma resuscitation care incorporating Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) compared to standard care for managing uncontrolled torso or lower body hemorrhage.
Methods: This study utilized a target trial design with a matched case-control methodology, emulating randomized 1 : 1 allocation for patients receiving trauma resuscitation care with or without the use of REBOA.
Am J Biol Anthropol
January 2025
Mandatory Center of Expertise for the Curation and Management of Archaeological Collections, St. Louis District, U.S. Army Corps of Engineers, St. Louis, Missouri, USA.
The collections of human remains within our university laboratories and classrooms are considered by many to be integral to teaching osteology. However, as an outgrowth of the Western scientific tradition of mind/body dualism, human remains within skeletal teaching collections are often regarded differently than those in museums or applied contexts. From processing to storage, the personhood of each individual becomes abstracted as we purchase, "inherit," handle, organize, and digitally scan their bones for teaching purposes.
View Article and Find Full Text PDFEmerg Med Australas
February 2025
Royal Prince Alfred Hospital, Camperdown, New South Wales, Australia.
Objective: To compare the frequency of clinically significant missed injuries in clinically stable trauma patients undergoing initial whole-body computed tomography (WBCT) versus selective imaging. Secondary objectives include comparisons of radiation exposure, incidental findings, ED length of stay (LOS), hospital LOS and mortality.
Methods: We performed a retrospective cohort study of trauma activations at a tertiary trauma centre in patients with normal vital signs from 1st January 2022 to 31st December 2022.
Asia Ocean J Nucl Med Biol
January 2025
Department of Nuclear Medicine, Saitama Medical University Hospital, Saitama, Japan.
Objectives: This study aimed to evaluate the quality and associated quantitative values of bone single-photon emission computed tomography (SPECT) with and without SwiftScan using a semiconductor camera equipped with a cadmium-zinc-telluride detector.
Methods: Ten patients with bone metastases from prostate cancer who underwent list-mode SPECT/computed tomography using a whole-body semiconductor camera participated in this study. A total of 130 metastatic lesions from 10 patients were analyzed.
Eur J Nucl Med Mol Imaging
January 2025
Amsterdam UMC location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, The Netherlands.
Purpose: The aim of this study was to validate simplified methods for quantifying [Ga]Ga-FAPI-46 uptake against full pharmacokinetic modeling.
Methods: Ten patients with pancreatobiliary cancer underwent a 90-min dynamic PET/CT scan using a long axial field of view system. Arterial blood samples were used to establish calibrated plasma-input function from both continuous arterial sampling and image-derived input function (IDIF).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!