A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic Performance of Dengue NS1 and Antibodies by Serum Concentration Technique. | LitMetric

Dengue infection has been a public health problem worldwide, especially in tropical areas. A lack of sensitive diagnostic methods in the early phase of the illness is one of the challenging problems in clinical practices. We, herein, analyzed 86 sera of acute febrile patients, from both dengue and non-dengue febrile illness, to study the diagnostic performance of dengue diagnostics. When compared with detection by Polymerase Chain Reaction (PCR), dengue NS1 detection by enzyme-linked immunosorbent assay (ELISA) had the highest sensitivity of 82.4% (with 94.3% specificity), while NS1 by rapid diagnostic test (RDT) had 76.5% sensitivity. IgM detection by ELISA and RDT showed only 27.5% and 17.9% sensitivity, respectively. The combination of NS1 and IgM in RDT yielded a sensitivity of 78.4%, with 97.1% specificity. One of the essential steps in making a diagnosis from patient samples is the preparation process. At present, a variety of techniques have been used to increase the number of analytes in clinical samples. In this study, we focused on the sample concentration method. The sera were concentrated three times with the ultrafiltration method using a 10 kDa molecular weight cut-off membrane. The results showed an increase in the sensitivity of RDT-NS1 detection at 80.4%, with 100% specificity. When combining NS1 and IgM detection, the concentration method granted RDT an 82.4% sensitivity, with 100% specificity. In conclusion, serum concentration by the ultrafiltration method is a simple and applicable technique. It could increase the diagnostic performance of point-of-care dengue diagnostics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963119PMC
http://dx.doi.org/10.3390/tropicalmed8020117DOI Listing

Publication Analysis

Top Keywords

diagnostic performance
12
performance dengue
8
dengue ns1
8
serum concentration
8
dengue diagnostics
8
igm detection
8
ns1 igm
8
concentration method
8
ultrafiltration method
8
100% specificity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!