Background: The accuracy, precision, and repeatability by which the tibial sagittal plane can be found with imageless technology is currently unknown. The purpose of this study was to identify any differences between imageless and image-based technology to define the sagittal plane of the tibia.

Methods: A computed tomography (CT) was obtained of 18 cadavers with the knee fully extended. The surgical trans-epicondylar axis and several tibial rotation references were acquired on the CT scan. After a medial parapatellar approach, the same anatomical landmarks were acquired in vivo. In the horizontal plane, the angle between the surgical trans-epicondylar axis and the tibial rotational axes was assessed.

Results: Highest accuracy was found for posterior cruciate ligament (PCL)-anterior cruciate ligament (ACL, -1.48°, standard deviation [SD] 13.64; imageless), tibial medial condyle (TMC)-tibial lateral condyle (TLC, 1.72°, SD 4.24; image-based), the ACL-medial border of tibial tuberosity (MTT, -2.89°, SD 18.86; image-based). Highest precision was acquired with image-based technology: TMC-TLC (SD 4.24), PCL-ACL (SD 5.86), and PCL-medial third of tibial tuberosity (M3TT, SD 7.10). Excellent intraobserver and interobserver correlation coefficients were observed with image-based technology: PCL-MTT, anterior medial condyle (AMC)-anterior lateral condyle (ALC), and TMC-TLC (Intraobserver and interobserver correlation coefficients 0.90-0.98).

Conclusion: The tibial sagittal plane could be defined with highest accuracy, precision, and repeatability on a preoperative CT. Imageless methodology lacked the precision and repeatability of image-based technology. With the current pursuit of high accuracy and precision in total knee arthroplasty, the reference frame used to quantify implant position should be highly accurate and precise as well.

Level Of Evidence: IV, Case Series.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2023.02.039DOI Listing

Publication Analysis

Top Keywords

sagittal plane
16
image-based technology
16
tibial sagittal
12
accuracy precision
12
precision repeatability
12
surgical trans-epicondylar
8
trans-epicondylar axis
8
axis tibial
8
highest accuracy
8
cruciate ligament
8

Similar Publications

Due to the low contrast of abdominal CT (Computer Tomography) images and the similar color and shape of the liver to other organs such as the spleen, stomach, and kidneys, liver segmentation presents significant challenges. Additionally, 2D CT images obtained from different angles (such as sagittal, coronal, and transverse planes) increase the diversity of liver morphology and the complexity of segmentation. To address these issues, this paper proposes a Detail Enhanced Convolution (DE Conv) to improve liver feature learning and thereby enhance liver segmentation performance.

View Article and Find Full Text PDF

Analysis and prediction of condylar resorption following orthognathic surgery.

Sci Rep

January 2025

OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium.

Condylar resorption is a feared complication of orthognathic surgery. This study investigated condylar resorption in a cohort of 200 patients This allowed for a powerful update on incidence and risk factors. 9.

View Article and Find Full Text PDF

Multi-Planar Cervical Motion Dataset: IMU Measurements and Goniometer.

Sci Data

January 2025

Department of Anatomy and Anthropology, Faculty of Medical & Health Sciences, Tel- Aviv University, Tel-Aviv, 699780, Israel.

This data descriptor presents a comprehensive and replicable dataset and method for calculating the cervical range of motion (CROM) utilizing quaternion-based orientation analysis from Delsys inertial measurement unit (IMU) sensors. This study was conducted with 14 participants and analyzed 504 cervical movements in the Sagittal, Frontal and Horizontal planes. Validated against a Universal Goniometer and tested for reliability and reproducibility.

View Article and Find Full Text PDF

A Faster Walking Speed Is Important for Improving Biomechanical Function and Walking Performance.

J Appl Biomech

January 2025

Lancaster Medical School, Faculty of Health and Medicine, Lancaster University, Lancaster, United Kingdom.

This study compares joint kinematics and kinetics of young stroke survivors who walk <0.79 m/s (slow) or >0.80 m/s (fast) with reference to a healthy able-bodied group and provides clinical recommendations for guiding the gait rehabilitation of stroke survivors.

View Article and Find Full Text PDF

A valid novel ground reaction force distribution algorithm to determine midfoot kinetics of gait with a single force plate.

Gait Posture

December 2024

Marquette University, 1250 W. Wisconsin Ave, Milwaukee, WI 53233, United States; Shriners Children's Chicago, 2211 N. Oak Park Ave, Chicago, IL 60707, United States.

Background: Understanding midfoot joint kinetics is valuable for improved treatment of foot pathologies. Segmental foot kinetics cannot currently be obtained in a standard gait lab without the use of multiple force plates or a pedobarographic plate overlaid with a force plate due to the single ground reaction force (GRF) vector.

Research Question: Can an algorithm be created to distribute the GRF into multiple segmental vectors that will allow for calculation of accurate midfoot and ankle moments?

Methods: 20 pediatric subjects (10 typically developing, 10 with foot pathology) underwent multi-segment foot gait analysis using the Milwaukee Foot Model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!