Flow-mediated dilation (FMD) and muscle oxygen saturation (StO) are measurements utilized to assess macro- and microvascular function, respectively. Macro- and microvascular dysfunction may occur differently depending on the clinical condition. Since microvascular responsiveness can influence upstream conduit artery hemodynamics, the present study aimed to investigate whether a correlation between FMD and muscle StO parameters exists. Sixteen healthy, young individuals were enrolled in this study. Femoral artery FMD and tibial anterior muscle StO were evaluated by ultrasound and near-infrared spectroscopy, respectively. The FMD and muscle StO parameters were assessed by employing a vascular occlusion test (VOT). The oxygen resaturation rate was determined by calculating the upslope of StO immediately after occlusion and the magnitude of reperfusion as the difference between the highest and lowest StO value achieved during the reperfusion phase. The oxygen desaturation rate and the magnitude of desaturation during the VOT were also evaluated. A significant correlation between the FMD and oxygen resaturation rate (r = 0.628; = 0.009), magnitude of reperfusion (r = 0.568; = 0.022), oxygen desaturation rate (r = -0.509; = 0.044), and magnitude of desaturation (r = 0.644; = 0.007) was observed. This study demonstrated a moderate association between the femoral artery FMD and tibial anterior StO parameters in young individuals.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9965810PMC
http://dx.doi.org/10.3390/jcdd10020063DOI Listing

Publication Analysis

Top Keywords

femoral artery
12
young individuals
12
fmd muscle
12
muscle sto
12
sto parameters
12
association femoral
8
flow-mediated dilation
8
muscle oxygen
8
oxygen saturation
8
healthy young
8

Similar Publications

Unveiling the uncommon: hypoplasia of external iliac artery-a case report and literature review.

J Cardiothorac Surg

January 2025

Department of Cardiovascular Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050000, P. R. China.

The absence or dysplasia of the iliac artery(IA) is an exceedingly rare condition, with limited cases documented in the literature. In this report, we present a case of hypoplasia of the right external iliac artery (EIA) in a 69-year-old male patient. The patient presented with right lower abdominal pain attributed to an aneurysm of the right internal iliac artery (IIA), yet notably, there was no evidence of lower limb ischemia at the time of consultation.

View Article and Find Full Text PDF

Complex wound closure scenarios necessitate the development of advanced wound dressings that can effectively address the challenges of filling irregularly shaped wounds and managing fatigue failures encountered in daily patient activities. To tackle these issues, we develop a multifunctional hydrogel from natural polysaccharides and polypeptides with injectability and self-healing properties for promoting full-time and multipurpose wound healing. Synthesized through dynamic Schiff base linkages between oxidized hyaluronic acid (OHA), ε-polylysine (ε-PL), and quaternized chitosan (QCS), the OHA/ε-PL/QCS hydrogel can gel rapidly within 50 s.

View Article and Find Full Text PDF

Purpose Of Review: This review assesses the outcomes of coronary interventions in patients with liver cirrhosis and coronary artery disease (CAD), focusing on the clinical challenges posed by cirrhosis-related hemodynamic and coagulopathic changes. It highlights essential considerations for managing these patients, who have an increased risk of adverse events during coronary procedures.

Recent Findings: Recent studies have shown that patients with liver cirrhosis undergoing PCI experience significantly higher mortality rates compared to non-cirrhotic patients, particularly in the context of STEMI and NSTEMI.

View Article and Find Full Text PDF

Emergency bleeding presents significant challenges such as high blood flow and rapid hemorrhaging. However, many existing hemostatic bandages face limitations, including the uncontrolled release of hemostatic agents, insufficient mechanical strength, poor adhesion, and complex manufacturing processes. To address these limitations, we developed a multifunctional hydrogel bandage for emergency hemostasis using a one-pot synthesis method.

View Article and Find Full Text PDF

Measurement of blood flow during exercise is crucial for understanding physiological responses and performance outcomes. However, traditional methods are often invasive, costly, or require substantial training, limiting widespread research in this area. This study introduces the innovative use of limb-affixed ultrasound probe holders for vascular imaging during exercise to overcome these challenges.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!