A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

ArgoCap - feasibility and safety of a novel over-the-scope device to facilitate endoscopic APC treatment. | LitMetric

Introduction: Argon plasma coagulation (APC) is an electrosurgical procedure used, among other indications, for treatment of dysplastic Barrett's mucosa. Homogeneous and safe application can be compromised by varying distances and suboptimal angle of the probe to the tissue. In this study, we present ArgoCap, a novel endoscopic device developed to facilitate endoluminal APC treatment. Objectives of this preclinical study were to assess feasibility and safety and to determine suitable APC settings.

Material And Methods: One-hundred and thirty-two APC treatments of predefined areas using various APC settings were performed in the opened porcine esophagus. Depth of thermal injury was assessed histologically. Feasibility of APC treatment in different locations was examined in 20 explanted porcine esophagi and in first porcine applications.

Results: APC treatment in all quadrants of the esophagus was feasible. Histologically, thermal effects involving the whole thickness of the mucosa were visible with all settings. APC with pulsed mode resulted in deep thermal damage with all power settings. No lesions of the muscular layer occurred using precise (E8, E9) and forced (10 W, 20 W) mode.

Conclusions: Esophageal APC using ArgoCap is feasible and safe. The device has the potential to improve APC treatment of larger mucosal areas.

Download full-text PDF

Source
http://dx.doi.org/10.1080/13645706.2023.2180322DOI Listing

Publication Analysis

Top Keywords

apc treatment
20
apc
11
feasibility safety
8
treatment
6
argocap feasibility
4
safety novel
4
novel over-the-scope
4
over-the-scope device
4
device facilitate
4
facilitate endoscopic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!