A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Breast Density Analysis Using Digital Breast Tomosynthesis. | LitMetric

We evaluated an automated percentage of breast density (BD) technique (PD) with digital breast tomosynthesis (DBT) data. The approach is based on the wavelet expansion followed by analyzing signal dependent noise. Several measures were investigated as risk factors: normalized volumetric; total dense volume; average of the DBT slices (slice-mean); a two-dimensional (2D) metric applied to the synthetic images; and the mean and standard deviations of the pixel values. Volumetric measures were derived theoretically, and PD was modeled as a function of compressed breast thickness. An alternative method for constructing synthetic 2D mammograms was investigated using the volume results. A matched case-control study (n = 426 pairs) was analyzed. Conditional logistic regression modeling, controlling body mass index and ethnicity, was used to estimate odds ratios (ORs) for each measure with 95% confidence intervals provided parenthetically. There were several significant findings: volumetric measure [OR = 1.43 (1.18, 1.72)], which produced an identical OR as the slice-mean measure as predicted; [OR =1.44 (1.18, 1.75)] when applied to the synthetic images; and mean of the pixel values (volume or 2D synthetic) [ORs ~ 1.31 (1.09, 1.57)]. PD was modeled as 2 degree polynomial (concave-down): its maximum value occurred at 0.41×(compressed breast thickness), which was similar across case-control groups, and was significant from this position [OR = 1.47 (1.21, 1.78)]. A standardized 2D synthetic image was produced, where each pixel value represents the percentage of BD above its location. The significant findings indicate the validity of the technique. Derivations supported by empirical analyses produced a new synthetic 2D standardized image technique. Ancillary to the objectives, the results provide evidence for understanding the percentage of BD measure applied to 2D mammograms. Notwithstanding the findings, the study design provides a template for investigating other measures such as texture.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9948963PMC
http://dx.doi.org/10.1101/2023.02.10.527911DOI Listing

Publication Analysis

Top Keywords

breast density
8
digital breast
8
breast tomosynthesis
8
applied synthetic
8
synthetic images
8
pixel values
8
breast thickness
8
breast
6
synthetic
6
density analysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!