Study Design: Retrospective cohort study.

Objective: Our objective was to determine whether lateral pedicle screw breach affects fusion rates and patient-reported outcomes in lumbar fusion surgery.

Summary Of Background Data: Although lateral pedicle screw malposition is considered relatively benign, few studies have focused specifically on clinical outcomes or fusion rates associated with lateral screw malposition.

Methods: Twelve-month postoperative computed tomography scans were reviewed for lateral breach, severity of breach, and fusion status. Patients with lateral breach were compared with patients with no breach. Outcome measures included Numerical Pain Rating Scale for back and leg pain, Oswestry Disability Index, and SF-36 physical function (SF-36 PF). Multivariable linear and logistic regression and were adjusted for age, procedure, level, and/or baseline pain score.

Results: Forty-five patients (31%) demonstrated 1 or more lateral breaches as compared with 99 patients without breach. After adjusting for baseline scores and fusion level, patients with 2 or more screw breaches experienced SF-36 PF score improvements that were 3.43 points less ( P =0.016) than patients with no lateral breach. After adjusting for baseline Numerical Pain Rating Scale, there was also a significant decrease in the odds of achieving minimally clinical important difference in back pain relief in these patients. There was no observed effect of lateral breach on the odds of successful fusion.

Conclusions: The current study did not observe an association between laterally malpositioned pedicle screws and nonunion. However, results are consistent with a negative effect on SF-36 PF scores and self-reported back pain at 12 months.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BSD.0000000000001440DOI Listing

Publication Analysis

Top Keywords

lateral breach
16
lateral pedicle
12
pedicle screw
12
lateral
9
screw malposition
8
breach
8
breach fusion
8
fusion rates
8
patients lateral
8
compared patients
8

Similar Publications

Background: Spinal stabilization in dogs is challenging, and improper implant placement can result in significant morbidity. Objectives were to evaluate reliability of a ball-tipped probe for detection of breached versus non-breached pedicle drill tracts in a canine large breed cadaveric model. CT scans obtained from T6 to sacrum.

View Article and Find Full Text PDF

Objective: We aimed to assess percutaneous pedicle screw (PPS) placement accuracy, fluoroscopy shot number, and operation time using a modified single anterior-posterior (AP) fluoroscopy with a C-arm in treating traumatic thoracic and lumbar vertebral fractures.

Methods: In total, 164 patients with single-level traumatic thoracic or lumbar fracture who underwent 6 PPS placements between April 2018 and September 2020 were divided into 2 groups. Conventional AP combined lateral fluoroscopy was used in Group A, whereas modified single AP fluoroscopy was used in Group B.

View Article and Find Full Text PDF

Dorsal Cortical Screw Penetration in Volar Distal Radius Plating: Comparison of 3 Fluoroscopic Views.

Plast Reconstr Surg Glob Open

November 2024

Department of Orthopedics and Trauma Surgery EOC, Tessin, Switzerland.

Background: The skyline or dorsal tangential view (DTV) and the carpal shoot-through (CST) have been developed to enhance the intraoperative examination of the distal radius's dorsal cortex during open reduction and internal fixation with volar plates. This study aimed to assess the lateral view (LV), DTV, and CST's effectiveness in showcasing screws that penetrate the dorsal cortex.

Methods: Eighty patients, comprised of 42 women and 38 men with an average age of 53 years, underwent volar locking plate fixation for displaced distal radius fractures.

View Article and Find Full Text PDF

Introduction: Pedicle screw placement plays a crucial role in treating various cases such as fractures, scoliosis, degenerative spine issues, and kyphosis, reinforcing all three spinal columns simultaneously. While three-dimensional navigation-assisted pedicle screw placement is considered superior, the freehand technique relies on anatomical landmarks and tactile feedback, with observed low complication rates.

Materials And Methods: This was a prospective single-center study conducted over a period of 3 years.

View Article and Find Full Text PDF
Article Synopsis
  • Accuracy in surgeries with pedicle screws is essential for treating lumbar instability, prompting this study to pinpoint the best screw entry points and angles.
  • The research compared traditional intersection technique placements with those designed using 3D simulations, analyzing 32 cases of lumbar degenerative spondylolisthesis from surgeries conducted between 2018 and 2023.
  • Results show that the intersection technique risked upper facet damage in many cases, while adjustments made in the 3D simulation led to significantly safer screw placements, especially at the L1, L2, and L5 segments.
View Article and Find Full Text PDF