Purpose: The Italian Registry of Contrast Material use in Cardiac Computed Tomography (iRCM-CCT) is a multicenter, multivendor, observational study on the use of contrast media (CM) in patients undergoing cardiac computed tomography (CCT). The aim of iRCM-CCT is to assess image quality and safety profile of intravenous CM compounds.

Materials And Methods: iRCM-CCT enrolled 1842 consecutive patients undergoing CCT (≥50 per site) at 20 cluster sites with the indication of suspected coronary artery disease. Demographic characteristics, CCT, and CM protocols, clinical indications, safety markers, radiation dose reports, qualitative (ie, poor vascular enhancement) and quantitative (ie, HU attenuation values) image parameters were recorded. A centralized coordinating center collected and assessed all image parameters.

Results: The cohort included 891 men and 951 women (age: 63±14 y, body mass index: 26±4 kg/m2) studied with ≥64 detector rows computed tomography scanners and different iodinated intravenous CM protocols and compounds (iodixanol, iopamidol, iohexol, iobitridol, iopromide, and iomeprol). The following vascular attenuation was reported: 504±147 HU in the aorta, 451±146 HU in the right coronary artery, 474±146 HU in the left main, 451±146 HU in the left anterior descending artery, and 441±149 HU in the circumflex artery. In 4% of cases the image quality was not satisfactory due to poor enhancement. The following adverse reactions to CM were recorded: 6 (0.3%) extravasations and 17 (0.9%) reactions (11 mild, 4 moderate, 2 severe).

Conclusions: In a multicenter registry on CM use during CCT the prevalence of CM-related adverse reactions was very low. The appropriate use of CM is a major determinant of image quality.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RTI.0000000000000644DOI Listing

Publication Analysis

Top Keywords

computed tomography
20
cardiac computed
16
contrast material
12
material cardiac
12
image quality
12
multicenter multivendor
8
italian registry
8
registry contrast
8
patients undergoing
8
coronary artery
8

Similar Publications

Background: Intermediate-high risk pulmonary embolism (PE) carries a significant risk of hemodynamic deterioration or death. Treatment should balance efficacy in reducing clot burden with the risk of complications, particularly bleeding. Previous studies on high-dose, short-term thrombolysis with alteplase (rtPA) showed a reduced risk of hemodynamic deterioration but no change in mortality and increased bleeding complications.

View Article and Find Full Text PDF

Objective: To investigate differences in arterial involvement patterns on F-FDG PET-CT between predominant cranial and isolated extracranial phenotypes of giant cell arteritis (GCA).

Methods: A retrospective review of F-FDG PET-CT findings was conducted on 140 patients with confirmed GCA. The patients were divided into two groups: the cranial group, which presented craniofacial ischemic symptoms either at diagnosis or during follow-up, and the isolated extracranial group which never exhibited such manifestations.

View Article and Find Full Text PDF

Early Lung Adenocarcinoma Manifesting as Irregular Subsolid Nodules: Clinical and CT Characteristics.

Acad Radiol

December 2024

Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuzhong District, Chongqing 400016, China (P.-l.Z., T.-y.L., F.-j.L., Q.L.). Electronic address:

Rationale And Objectives: To explore the clinical and computed tomography (CT) characteristics of early-stage lung adenocarcinoma (LADC) that presents with an irregular shape.

Materials And Methods: The CT data of 575 patients with stage IA LADC and 295 with persistent inflammatory lesion (PIL) manifesting as subsolid nodules (SSNs) were analyzed retrospectively. Among these patients, we selected 233 patients with LADC and 140 patients with PIL, who showed irregular SSNs, hereinafter referred to as irregular LADC (I-LADC) and irregular PIL (I-PIL), respectively.

View Article and Find Full Text PDF

Background: Multidose iodinated contrast media (ICM) injectors have shown promise in reducing ICM waste. This study aims to evaluate the impact of patient volume on ICM waste reduction in multidose injectors.

Methods: CT studies performed over one-year period with a multidose injector at our emergency CT unit.

View Article and Find Full Text PDF

A Double-Blind Randomized Crossover Trial Comparing the Esthetic Outcomes Of CAD-CAM Provisional Restorations Fabricated Using CBCT And IOS Acquisition Methods.

J Dent

December 2024

Professor and Clinic director, Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich Switzerland. Electronic address:

Objectives: This double-blind randomised crossover trial aimed to compare the aesthetic outcomes of CAD-CAM manufactured provisional restorations created using cone beam computed tomography (CBCT) and intraoral scanners (IOS) acquisition methods.

Methods: Twelve participants (mean-age: 38 ± 5 years) requiring full mouth rehabilitation were included in this crossover trial. Two sets of identical CAD-CAM provisional restorations, differing only in the method of data acquisition (A: CBCT, B: IOS), were fabricated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!