The design, validation, and application of a quantum-cascade-laser-absorption-spectroscopy diagnostic for measuring gas temperature, pressure, and nitric oxide (NO) in high-temperature air are presented. A distributed-feedback quantum-cascade laser (QCL) centered near 1976 was used to scan across two transitions of NO in its ground electronic state ( ). A measurement rate of 500 kHz was achieved using a single QCL by: (1) performing current modulation through a bias-tee, and (2) targeting closely spaced transitions with a large difference in lower-state energy. The diagnostic was validated in a mixture of 95% argon and 5% NO, which was shock-heated to ≈2000 to 3700 K. The average mean percent differences between laser-absorption-spectroscopy (LAS) measurements and predictions from shock-jump relations for temperature, pressure, and NO mole fraction were 3.1%, 4.1%, and 6.5%, respectively. The diagnostic was then applied to characterize shock-heated air at high temperatures (up to ≈5500) and high pressures (up to 12 atm) behind either incident or reflected shocks. The LAS measurements were compared to theoretical predictions from shock-jump relations, pressure sensors mounted in the wall of the shock tube, and equilibrium values of the NO mole fraction. The average mean percent differences between LAS measurements and their aforementioned reference values were 3.2%, 10.8%, and 10.4% for temperature, pressure, and NO mole fraction, respectively. Last, a comparison between a measured NO mole fraction time history and a time-stepped homogeneous reactor simulation performed using two different chemical kinetics mechanisms is presented.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.464623DOI Listing

Publication Analysis

Top Keywords

temperature pressure
16
mole fraction
16
las measurements
12
quantum-cascade-laser-absorption-spectroscopy diagnostic
8
shock-heated air
8
average percent
8
percent differences
8
predictions shock-jump
8
shock-jump relations
8
pressure mole
8

Similar Publications

The density (ρ), speed of sound (), and refractive index ( ) of ,-dimethylacetamide (DMA) with 1-butanol, 1-pentanol, furfural (FFL), or furfuryl alcohol (FA) as a function of composition and at = 293.15 to 323.15 K with an interval of 10 K and atmospheric pressure were measured.

View Article and Find Full Text PDF

A novel balloon-type photoacoustic cell (BTPAC) is proposed to facilitate the detection limitations of acetylene (CH) gas achieving ppb level. Here, an ellipsoidal photoacoustic cavity is employed as the platform for gas-light interaction. By strategically directing the excitation source towards the focal point of the ellipsoidal cavity, ensuring its trajectory traverses the focal point upon each reflection from the interior walls.

View Article and Find Full Text PDF

The thermal conductivity of liquid -1,2-dichloroethene (R-1130(E)) was measured at temperatures ranging from 240 K to 340 K and pressures up to 25 MPa using a transient hot-wire instrument. A total of 447 thermal conductivity data points were measured along six isotherms. Each isotherm includes data at nine pressures, which were chosen to be at equal density increments starting at a pressure of 0.

View Article and Find Full Text PDF

An inevitable overoxidation process is considered as one of the most challenging problems in the direct conversion of methane (CH4) to methanol (CH3OH), which is limited by the uncontrollable cracking of key intermediates. Herein, we have successfully constructed a photocatalyst, the Fe-doped ZnO hollow polyhedron (Fe/ZnOHP), for the highly selective photoconversion of CH4 to CH3OH under mild conditions. In-situ experiments and density functional theory calculations confirmed that the introduction of Fe was able to decrease the energy level of the O 2p orbital, which passivated the activity of lattice oxygen in ZnO nanocrystals.

View Article and Find Full Text PDF

Background: Sepsis-associated encephalopathy (SAE) may be worsened by early systemic insults. We aimed to investigate the association of early systemic insults with outcomes of critically ill patients with severe SAE.

Methods: We performed a retrospective analysis using data from the French OUTCOMEREA prospective multicenter database.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!