Background: Proximal humeral shaft fractures are surgically challenging and plate osteosynthesis with a long straight plate is one operative treatment option in these patients although endangering the radial nerve distally. Helical plates potentially avoid the radial nerve by twisting around the humeral shaft. Aim of the study was to investigate in a human cadaveric model the biomechanical competence of helical plates versus straight lateral plates used for fixation of proximal third comminuted humeral shaft fractures.

Methods: Eight pairs of humeral cadaveric humeri were instrumented using either a long 90°-helical plate (Group1) or a straight long PHILOS plate (Group2). An unstable proximal humeral shaft fracture was simulated by means of a 5 cm osteotomy gap. All specimens were tested under quasi-static loading in axial compression, internal and external rotation, and bending in four directions. Subsequently, progressively increasing cyclic loading in internal rotation until failure was applied and interfragmentary movements were monitored by motion tracking.

Results: During static testing flexion/extension deformation in Group1 was significantly higher, however, varus/valgus deformation as well as shear and torsional displacement under torsional load remained statistically indifferent between both groups. During cyclic testing shear and torsional displacements were both significantly higher in Group1 compared to Group 2. However, cycles to catastrophic failure remained statistically indifferent between the groups.

Conclusions: From a biomechanical perspective, although 90°-helical plating is associated with higher initial stability against varus/valgus collapse and comparable endurance under dynamic loading, it demonstrates lower resistance to flexion/extension and internal rotation with bigger shear interfragmentary displacements versus straight lateral plating and, therefore, cannot be considered as its real alternative. Alternative helical plate designs should be investigated in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-023-04814-0DOI Listing

Publication Analysis

Top Keywords

humeral shaft
20
versus straight
12
proximal third
8
shaft fractures
8
proximal humeral
8
radial nerve
8
helical plates
8
straight lateral
8
internal rotation
8
shear torsional
8

Similar Publications

Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.

Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.

View Article and Find Full Text PDF

Humeral Shaft Stress Fracture Completion in a Weight Lifter: A Case Report.

JBJS Case Connect

January 2025

Department of Orthopedic Surgery and Rehabilitation Medicine, University of Chicago Medicine, Chicago, Illinois.

Case: A 34-year-old man, amateur weight lifter presented with acute worsening of right shoulder pain after 5 months of prodromal, progressive, atraumatic pain. Imaging showed a short oblique proximal third humeral shaft fracture without evidence of other osseous abnormalities. He was treated operatively with open reduction and internal fixation, healed uneventfully, and returned to weight lifting within 3 months.

View Article and Find Full Text PDF

Objectives: To describe operative results after humerus nonunion surgery in patients whose initial humerus shaft fracture (OTA/AO code 12) was treated nonoperatively and to identify risk factors of nonunion surgery failure in the same population.

Design: Case series.

Setting: Nine academic level 1 trauma centers.

View Article and Find Full Text PDF

Introduction: Gas gangrene, is an aggressive and life-threatening necrotizing infection of soft tissues. We report a case of upper-limb trauma resulting in clostridial gas gangrene.

Case Report: A 36-year-old healthy male presented to our department with a left humeral shaft fracture and an open elbow fracture.

View Article and Find Full Text PDF

: Supracondylar humerus fractures (SCHFs) are the most common pediatric elbow injuries and often require surgical intervention. Despite guidelines, optimal timing for surgical management, particularly for cases without neurovascular compromise, remains unclear. This study evaluates the influence of surgical timing on short-term outcomes, focusing on fracture reduction quality and surgical parameters.

View Article and Find Full Text PDF