Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The mass attenuation coefficient (MAC), effective atomic number (Z), equivalent atomic number (Z), fast neutron removal cross-section (FNRCS), energy absorption buildup factor (EABF), mass-energy absorption coefficient (MenAC), relative kerma, and computed tomography (CT) numbers were calculated for the alginates, bisphenol A-glycidyl methacrylate (Bis-GMA), chitin, hyaluronic acid, polycaprolactone (PCL), polyether ether ketone (PEEK), polyethylene glycol (PEG), polyglycolide (PGA), polylactic acid (PLA), poly lacto-co-glycolic acid (PLGA), poly methyl methacrylate (PMMA), poly vinyl alcohol (PVA), polyvinylpyrrolidone (PVP), triethylene glycol dimethacrylate (TEGDMA), and urethane dimethacrylate (UDMA) polymers using the Phy-X/PSD and Py-MLBUF software. The total stopping power (TSP) of electrons, protons, and alpha particles was calculated for the selected polymers using the ESTAR, PSTAR, and ASTAR programs. The effective atomic number for absorption and charged particle (electron, proton, alpha, and carbon ion) interactions were estimated for the selected polymers using Phy-X/ZeXTRa software. The FNRCS values of Bis-GMA, PCL, PEG, PMMA, and PVP were similar to those of the human tissues. For the selected polymers, the Z values for electron, proton, alpha, and carbon ion interactions of PCL, PEG, PLGA, and PVA were similar to those of human tissues, except for the cortical bone, across the entire energy range. These results are expected to assist in selecting suitable polymers as tissue-equivalent materials in the desired energy range for photon, neutron, and charged-particle interactions. This study is expected to be useful for radiation therapy and dosimetry.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12194-023-00704-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!