Purpose: To elucidate residual motion of cortical screw (CS) and pedicle screw (PS) constructs with unilateral posterior lumbar interbody fusion (ul-PLIF), bilateral PLIF (bl-PLIF), facet-sparing transforaminal lumbar interbody fusion (fs-TLIF), and facet-resecting TLIF (fr-TLIF).

Methods: A total of 35 human cadaver lumbar segments were instrumented with PS (n = 18) and CS (n = 17). Range of motion (ROM) and relative ROM changes were recorded in flexion/extension (FE), lateral bending (LB), axial rotation (AR), lateral shear (LS), anterior shear (AS), and axial compression (AC) in five instrumentational states: without interbody fusion (wo-IF), ul-PLIF, bl-PLIF, fs-TLIF, and fr-TLIF.

Results: Whereas FE, LB, AR, and AC noticeably differed between the instrumentational states, AS and LS were less prominently affected. Compared to wo-IF, ul-PLIF caused a significant increase in ROM with PS (FE + 42%, LB + 24%, AR + 34%, and AC + 77%), however, such changes were non-significant with CS. ROM was similar between wo-IF and all other interbody fusion techniques. Insertion of a second PLIF (bl-PLIF) significantly decreased ROM with CS (FE -17%, LB -26%, AR -20%, AC -51%) and PS (FE - 23%, LB - 14%, AR - 20%, AC - 45%,). Facet removal in TLIF significantly increased ROM with CS (FE + 6%, LB + 9%, AR + 17%, AC of + 23%) and PS (FE + 7%, AR + 12%, AC + 13%).

Conclusion: bl-PLIF and TLIF show similarly low residual motion in both PS and CS constructs, but ul-PLIF results in increased motion. The fs-TLIF technique is able to further decrease motion compared to fr-TLIF in both the CS and PS constructs.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00586-023-07597-5DOI Listing

Publication Analysis

Top Keywords

interbody fusion
20
residual motion
12
lumbar interbody
8
plif bl-plif
8
instrumentational states
8
wo-if ul-plif
8
rom
6
interbody
5
fusion
5
motion
5

Similar Publications

Background: There are differences in the extent of excision of articular processes, spinal processes and posterior ligamentum complexes (PLC) for posterior approach lumbar interbody fusion. Given that the biomechanical significance of these structures has been verified and that deterioration of the biomechanical environment is the main trigger for complications in both fused and adjacent motion segments, changes in decompression ranges may affect the potential risk of adjacent segmental disease (ASD) biomechanically; however, this topic has yet to be identified.

Methods: Posterior lumbar interbody fusion (PLIF) with different decompression strategies was simulated in a well-validated lumbosacral model.

View Article and Find Full Text PDF

The urgent etiological diagnosis represents the main management objective of cervical spondylodiscitis (CSD) to start as soon as possible antibiotic treatment to prevent neurological deterioration. The present study aimed to evaluate a multicenter experience implementing a minimally invasive surgical approach (MISA) to manage CSD such pathology vs the most complex and aggressive surgical strategies currently used.This retrospective multicenter study used a database of 70 patients from five European neurosurgical centers.

View Article and Find Full Text PDF

Pear-Shaped Disc as a Risk Factor for Postoperative Sclerotic Modic Changes After Transforaminal Lumbar Interbody Fusion.

Orthop Surg

January 2025

Department of Orthopaedic, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, Sichuan, China.

Objective: Pear-shaped disc could increase the risk of intraoperative end-plate injury, which may lead to postoperative sclerotic Modic Changes (MCs). However, there are no studies on the relationship between pear-shaped disc and postoperative sclerotic MCs. Therefore, this study investigates the risk factors for postoperative sclerotic MCs following transforaminal lumbar interbody fusion (TLIF).

View Article and Find Full Text PDF

Purpose: This study aims to (1) evaluate whether the endplate bone quality (EBQ) scores can independently predict adjacent segment disease (ASD); and (2) judge the predictive value of EBQ compared to vertebral bone quality (VBQ) for ASD after single-level transforaminal lumbar interbody fusion (TLIF).

Methods: A single-center retrospective analysis was conducted of patients undergoing single-level TLIF for degenerative spinal disease from 2014 to 2020. Demographic, surgery, and radiographic data were collected.

View Article and Find Full Text PDF

Study Design: A meta-analysis approach to a systematic review.

Objective: Perform a systematic review to identify all reports directly comparing outcomes of lateral lumbar interbody fusion (LLIF) using static versus expandable interbody cages. Specifically focusing on periprocedural complications, intraoperative morbidity, and fusion outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!