Objective: To determine independent factors related to the use of oxygen and the oxygen flow rate in idiopathic pulmonary fibrosis (IPF) patients placed on a lung transplant waitlist and undergoing pulmonary rehabilitation (PR).

Methods: This was a retrospective quasi-experimental study presenting functional capacity and health-related quality of life (HRQoL) data from lung transplant candidates with IPF referred for PR and receiving ambulatory oxygen therapy. The patients were divided into three groups on the basis of the oxygen flow rate: 0 L/min (the control group), 1-3 L/min, and 4-5 L/min. Data on functional capacity were collected by means of the six-minute walk test, and data on HRQoL were collected by means of the Medical Outcomes Study 36-item Short-Form Health Survey (SF-36), being collected before and after 36 sessions of PR including aerobic and strength exercises.

Results: The six-minute walk distance improved in all three groups (0 L/min: Δ 61 m, p < 0.001; 1-3 L/min: Δ 58 m, p = 0.014; and 4-5 L/min: Δ 35 m, p = 0.031). Regarding HRQoL, SF-36 physical functioning domain scores improved in all three groups, and the groups of patients receiving ambulatory oxygen therapy had improvements in other SF-36 domains, including role-physical (1-3 L/min: p = 0.016; 4-5 L/min: p = 0.040), general health (4-5 L/min: p = 0.013), social functioning (1-3 L/min: p = 0.044), and mental health (1-3 L/min: p = 0.046).

Conclusions: The use of ambulatory oxygen therapy during PR in lung transplant candidates with IPF and significant hypoxemia on exertion appears to improve functional capacity and HRQoL.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970614PMC
http://dx.doi.org/10.36416/1806-3756/e20220280DOI Listing

Publication Analysis

Top Keywords

1-3 l/min
20
ambulatory oxygen
16
oxygen therapy
16
4-5 l/min
16
lung transplant
12
functional capacity
12
three groups
12
l/min
11
therapy lung
8
idiopathic pulmonary
8

Similar Publications

Unlabelled: Cardiorespiratory fitness can be assessed by direct, indirect, maximal, and moderate effort, running, cycling, or walking methods.

Objective: To predict maximum oxygen consumption (V O2max) from the six-minute walk test in schoolchildren.

Patients And Method: 459 students were included, 215 were male and 244 were female, aged 11.

View Article and Find Full Text PDF

Background: Oral treatment with the exogenous ketone body 3-hydroxybutyrate improves cardiac function in patients with heart failure with reduced ejection fraction, but ketosis is limited to 3 to 4 hours. Treatment with (R)-1,3-butanediol (BD) provides prolonged ketosis in healthy controls, but the hemodynamic and metabolic profile is unexplored in patients with heart failure with reduced ejection fraction.

Methods And Results: This was a randomized, single-blind, placebo-controlled, crossover study.

View Article and Find Full Text PDF

Temporary microaxial transvalvular left ventricular assist device for post-myocardial infarction ventricular septal rupture: Bridging a paradigm shift.

JTCVS Tech

December 2024

Department of Thoracic and Cardiovascular Surgery, Kaufman Center for Heart Failure Treatment and Recovery, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio.

Objective: To characterize the clinical courses and outcomes of patients presenting with post-myocardial infarction (MI) ventricular septal rupture (VSR) receiving temporary microaxial transvalvular left ventricular assist device (tVAD) support.

Methods: Between December 2019 and July 2023, 10 consecutive patients presented with a post-MI VSR. All 10 patients received a tVAD.

View Article and Find Full Text PDF

Rationale And Objectives: Increased aortic or central arterial stiffness (CAS) is a major factor in cardiovascular morbidity and mortality in patients with vascular risk factors. Decreased glomerular filtration rate (GFR) and increased urinary albumin excretion (uALB) are associated with lethal and non-lethal cardiovas-cular events. The pathophysiological mechanisms of this association are not fully defined.

View Article and Find Full Text PDF

Cardiac output can be estimated non-invasively by electrical cardiometry with the ICON® monitor (Osypka Medical GmbH, Berlin, Germany). Conflicting results have been reported regarding the cardiac output measurement performance of electrical cardiometry. In this prospective method comparison study, we compared cardiac output measured using electrical cardiometry (EC-CO; test method) with cardiac output measured using intermittent pulmonary artery thermodilution (PATD-CO; reference method) in patients after coronary artery bypass graft (CABG) surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!