Square wave voltammetry (SWV) is a voltammetric technique for measuring Faradaic current while minimizing contributions from non-Faradaic processes. In square wave voltammetry, the potential waveform applied to a working electrode and the current sampling protocols followed are designed to minimize contributions from non-Faradaic processes (i.e., double layer charging) to improve voltammetric sensitivity. To achieve this, the current is measured at the end of each forward and reverse potential pulse after allowing time for non-Faradaic currents to decay exponentially. A consequence of sampling current at the end of a potential pulse is that the current data from the preceding time of the potential pulse are discarded. These discarded data can provide information about the non-Faradaic contributions as well as information about the redox system including charge transfer rates. In this paper, we introduce continuous square wave voltammetry (cSWV), which utilizes the continuous collection of current to maximize the information content obtainable from a single voltammetry sweep eliminating the need for multiple scans. cSWV enables acquiring a multitude of voltammograms corresponding to various frequencies and, thus, different scan rates from a single sweep. An application that benefits significantly from cSWV is conformation switching, functional nucleic acid sensors. We demonstrate the utility of cSWV on two representative small molecules targeting electrochemical, aptamer-based sensors. Moreover, we show that cSWV provides comparable results to those obtained from traditional square wave voltammetry, but with cSWV, we are able to acquire dynamic information about the sensor surfaces enabling rapid calibration and optimization of sensing performance. We also demonstrate cSWV on soluble redox markers. cSWV can potentially become a mainstay technique in the field of conformation switching sensors.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9936610 | PMC |
http://dx.doi.org/10.1021/acsmeasuresciau.2c00044 | DOI Listing |
Sensors (Basel)
December 2024
Technical Faculty in Bor, University of Belgrade, Vojske Jugoslavije 12, P.O. Box 50, 19210 Bor, Serbia.
Cadmium is one of the most dangerous pollutants found in the environment, where it exists mainly due to human activities. High cadmium concentrations can cause serious problems, which is why the detection and determination of Cd is one of the most important tasks. Electroanalytical methods provide rapid and accurate results in the detection of cadmium in various solutions.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Electrical Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan.
This paper proposes a hybrid algorithm combining the symmetrized dot pattern (SDP) method and a convolutional neural network (CNN) for fault detection in lithium battery modules. The study focuses on four fault types: overcharge, over-discharge, aging, and leakage caused by manual perforation. An 80.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Institute for Pulsed Power and Microwave Technology IHM, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany.
Estimating the effective permittivity of anisotropic fibrous media is critical for advancing electromagnetic applications, requiring detailed microstructural and orientation analyses. This study introduces innovative approaches for disclosing the orientation and microstructure of fibers, leading to mixing relations. It particularly focuses on two specific fiber configurations: 1.
View Article and Find Full Text PDFFood Chem
January 2025
College of Food and Bioengineering, Xihua University, Chengdu 610039, China.
This study developed an electrochemical immunosensor for the detection of aflatoxin B1 (AFB1) in vegetable oil, based on an electrochemical modified carbon cloth (EMCC) electrode modified with a composite functional layer of cross-linked o-aminothiophenol functionalized AuNPs (o-ATP@AuNPs)/Prussian Blue (PB). The EMCC electrode substrate was prepared by modifying carbon cloth through electrochemical methods to increase its surface area, which allowed for the effective deposition of o-ATP@AuNPs/PB composite functional layer and improved the conductivity of the electrode material. The synergistic effect of o-ATP@AuNPs and PB significantly enhanced the sensitivity of the electrochemical sensor.
View Article and Find Full Text PDFTalanta
January 2025
Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh, 11533, Saudi Arabia. Electronic address:
Envenomation accidents are usually diagnosed at the hospital through signs and symptoms assessment such as short breath, dizziness and vomiting, numbness, swilling, bruising, or bleeding around the affected site. However, this traditional method provides inaccurate diagnosis given the interface between snakebites and scorpion stings symptoms. Therefore, early determination of bites/stings source would help healthcare professionals select the suitable treatment for patients, thus improving envenomation management.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!