A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Factors associated with implantable cardioverter-defibrillator shocks in patients suffering from non-ischemic cardiomyopathy. | LitMetric

Factors associated with implantable cardioverter-defibrillator shocks in patients suffering from non-ischemic cardiomyopathy.

ARYA Atheroscler

Assistant Professor, Heart Failure Research Center, Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran.

Published: May 2022

Background: Although intra-cardiac shocks are a lifesaving approach in patients with systolic heart failure (HF), the probable effective factors related to shock occurrence are less frequently recognized. We designed this study to assess the factors associated with inappropriate or appropriate implantable cardioverter-defibrillator (ICD) shocks in patients with non-ischemic cardiomyopathy (NICM).

Methods: Ninety-nine patients with NICM who implanted ICD were enrolled from March 2018 to September 2019 and followed up with a three-month interval for up to one year. Shock therapy was defined as either appropriate or inappropriate shock. The odds ratio (OR) of inappropriate shock occurrence was calculated with crude and different adjusted models.

Results: The mean age of the population at baseline was 51.9 ± 15.4 years (men: 71%). Baseline data revealed that patients with inappropriate shocks had higher heart rates (HR), worse New York Heart Association (NYHA) class, and anti-tachycardia pacing (ATP) as well as higher percentages of amiodarone usage compared to groups with appropriate or no shock [HR: 96.8 ± 27.8 vs. 79.8 ± 12.1 vs. 76.2 ± 17.6 beats per minute (bpm), P = 0.014; NYHA class IV: 85.7% vs. 74.1% vs. 63.4%, P = 0.041; ATP: 37.5% vs. 29% vs. 5%, P = 0.010; amiodarone usage: 37.5% vs. 25.8% vs. 5%, P = 0.23, respectively]. Further multiple-adjusted OR did not reveal any significant independent association between the aforementioned variables and inappropriate shock incidence.

Conclusion: This study indicates no significant independent predisposing factor in the occurrence of inappropriate shocks among patients with NICM. Other studies are required in this regard.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931942PMC
http://dx.doi.org/10.48305/arya.2022.24342DOI Listing

Publication Analysis

Top Keywords

shocks patients
12
inappropriate shock
12
factors associated
8
implantable cardioverter-defibrillator
8
non-ischemic cardiomyopathy
8
shock occurrence
8
patients nicm
8
inappropriate shocks
8
nyha class
8
amiodarone usage
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!