  • Pulmonary artery hypertension (PAH) is a serious complication of congenital heart disease (CHD), leading to poorer health outcomes, and Doppler echocardiography (DE) is a vital tool for its diagnosis and monitoring.
  • In a study of 64 CHD patients, DE was found to have a modest correlation with right heart catheterization (RHC) in estimating pulmonary artery systolic pressure (PASP), with a significant agreement in results.
  • Combining DE with NTproBNP/BNP measurements resulted in excellent diagnostic performance, achieving 100% sensitivity and displaying high predictive values for identifying PAH in these patients.

Article Abstract

Background: Pulmonary artery hypertension (PAH) is a common complication of congenital heart disease (CHD) and is associated with worse outcomes and increased mortality. The Doppler echocardiography (DE) is a commonly used imaging tool for both diagnosis and follow-up examination of PAH. Here is to evaluate the diagnostic performance of DE combined with NTproBNP/BNP as screening strategy in PAH patients with CHD.

Methods: A retrospective study in 64 patients with CHD has been carried out to compare estimate pulmonary artery systolic pressure (PASP) measured with DE to that measured with right heart catheterization (RHC). The Pearson correlation analyses were used to calculate the correlation coefficients between RHC and DE. The Bland-Altman analyses were carried out to assess the agreement between the two methods. ROC analyses were used to evaluate the diagnostic performance of DE, NTproBNP/BNP, and DE combined with NTproBNP/BNP.

Results: Our data have demonstrated that a mild correlation ( = 0.4401, < 0.01) was observed between PASP (78.1 ± 29.0 mmHg) measured during RHC and PASP (74.9 ± 19.7 mmHg) as estimated using DE. The Bland-Altman analysis demonstrated that the bias for DE PASP estimates was 3.2 mmHg with 95% limits of agreement ranging from -49.53 to 55.90 mmHg. The results of DE showed an AUC of 0.848 (95% CI = 0.666-1; < 0.001), the sensitivity of which was 98.3% and the specificity was 77.8%. The AUC of NTproBNP/BNP for the identification of PAH was 0.804 (95% CI = 0.651-0.956; < 0.001), the sensitivity of which was 81.4% and the specificity was 87.5%. The AUC of DE combined with NTproBNP/BNP was 0.857 (95% CI = 0.676-1; < 0.001), of which sensitivity was 100% and specificity was 77.8%. The positive predictive value (PPV) and negative predictive value (NPV) were 96.6% and 100%, respectively.

Conclusions: Our study shows that the Doppler echocardiography combined with NTproBNP/BNP has better diagnostic performance in pulmonary artery hypertension associated with congenital heart disease, especially when DE negative screening in PAH patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9940967PMC
http://dx.doi.org/10.1155/2023/1896026DOI Listing

Publication Analysis

Top Keywords

combined ntprobnp/bnp
16
pulmonary artery
16
doppler echocardiography
12
artery hypertension
12
congenital heart
12
heart disease
12
diagnostic performance
12
0001 sensitivity
12
echocardiography combined
8
hypertension associated
8

Similar Publications

Article Synopsis
  • Pulmonary artery hypertension (PAH) is a serious complication of congenital heart disease (CHD), leading to poorer health outcomes, and Doppler echocardiography (DE) is a vital tool for its diagnosis and monitoring.
  • In a study of 64 CHD patients, DE was found to have a modest correlation with right heart catheterization (RHC) in estimating pulmonary artery systolic pressure (PASP), with a significant agreement in results.
  • Combining DE with NTproBNP/BNP measurements resulted in excellent diagnostic performance, achieving 100% sensitivity and displaying high predictive values for identifying PAH in these patients.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!