Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The primary aim was to assess whether a short (125 millimeter (mm)) stem offered an equivalent hip-specific function compared to the standard (150 mm) stem when used for cemented total hip arthroplasty. Secondary aims were to evaluate health-related quality of life, patient satisfaction, stem height and alignment, as well as radiographic loosenings and complications between the two stems.
Methods: A prospective twin-center double-blind randomized control trial was conducted. During a 15-month period, 220 patients undergoing total hip arthroplasty were randomized to either a standard (n = 110) or a short (n = 110) stem. There were no significant (P ≥ .065) differences in preoperative variables between the groups. Functional outcomes and radiographic assessment were undertaken at a mean of 1 and 2 years.
Results: There were no differences (P = .428) in hip-specific function according to the mean Oxford hip scores at 1 year (primary endpoint) or at 2 years (P = .622) between the groups. The short stem group had greater varus angulation (0.9 degrees, P = .003) when compared to the standard group and were more likely (odds ratio 2.42, P = .002) to have varus stem alignment beyond one standard deviation from the mean. There were no significant (P ≥ .083) differences in the forgotten joint scores, EuroQol-5-Dimension, EuroQol-visual analogue scale, short form 12, patient satisfaction, complications, stem height, or radiolucent zones at 1 or 2 years between the groups.
Conclusion: The cemented short stem used in this study had equivalent hip-specific function, health-related quality of life, and patient satisfaction when compared to the standard stem at mean 2 years post operation. However, the short stem was associated with a greater rate of varus malalignment, which may influence future implant survival.