A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Leadless versus transvenous single-chamber ventricular pacemakers: 3 year follow-up of the Micra CED study. | LitMetric

Introduction: The Micra Coverage with Evidence Development (CED) Study is a novel comparative analysis of Micra (leadless VVI) and transvenous single-chamber ventricular pacemakers (transvenous VVI) using administrative claims data. To compare chronic complications, device reinterventions, heart failure hospitalizations, and all-cause mortality after 3 years of follow-up.

Methods: US Medicare claims data linked to manufacturer device registration information were used to identify Medicare beneficiaries with a de novo implant of either a Micra VR leadless VVI or transvenous VVI pacemaker from March 9, 2017 to December 31, 2018. Unadjusted and propensity score overlap-weight adjusted Fine-Gray competing risk models were used to compare outcomes at 3 years.

Results: Leadless VVI patients (N = 6219) had a 32% lower rate of chronic complications and a 41% lower rate of reintervention compared with transvenous VVI patients (N = 10 212) (chronic complication hazard ratio [HR] 0.68; 95% confidence interval [CI], 0.59-0.78; reintervention HR 0.59; 95% CI 0.44-0.78). Infections rates were significantly lower among patients with a leadless VVI (<0.2% vs. 0.7%, p < .0001). Patients with a leadless VVI also had slightly lower rates of heart failure hospitalization (HR 0.90; 95% CI 0.84-0.97). There was no difference in the adjusted 3-year all-cause mortality rate (HR 0.97; 95% CI, 0.92-1.03).

Conclusion: This nationwide comparative evaluation of leadless VVI versus transvenous VVI de novo pacemaker implants demonstrated that the leadless group had significantly fewer complications, reinterventions, heart failure hospitalizations, and infections than the transvenous group at 3 years, confirming that the previously reported shorter-term advantages associated with leadless pacing persist and continue to accrue in the medium-to-long-term.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.15863DOI Listing

Publication Analysis

Top Keywords

leadless vvi
16
transvenous vvi
12
transvenous single-chamber
8
single-chamber ventricular
8
ventricular pacemakers
8
ced study
8
micra leadless
8
vvi transvenous
8
claims data
8
chronic complications
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!