Background: Identify idiopathic ventricular tachycardia in patients with ventricular premature beats was required to have effectively treatment.

Hypothesis: The aim of this study is to investigate the predictive value of Tp-Te interval, Tp-Te/QT ratio, and QRS-T angle of idiopathic ventricular tachycardia in patients with idiopathic ventricular premature beats.

Methods: One hundred and seventy-eight patients who had undergone premature ventricular complex/ventricular tachycardia (PVC/VT) ablation between January 1, 2020 and August 30, 2022 constituted our study population as ventricular arrhythmia group. Seventy-five healthy people were selected as control group. Patients with no episode of VT were classified as PVC group, while with any episode of VT that has the same morphology with PVC were classified as PVC with VT group. Patients in PVC with VT group were divided into two groups: nonsustained VT group (duration of any episode of VT below 30 s) and sustained VT group (duration of any episode of VT over 30 s). Tp-Te interval, Tp-Te/QT ratio and QRS-T angle were compared in groups.

Results: Tp-Te interval, Tp-Te/QT ratio and patients with increased QRS-T angle in PVC with VT group were higher or more than those in PVC group (p < .001). The value of combined diagnosis of these indexes was higher. Tp-Te interval was longer in the sustained VT group compared to the nonsustained VT group (p = .009).

Conclusion: Tp-Te interval, Tp-Te/QT ratio, and QRS-T angle may have a predictive value of presence of idiopathic VT in patients with premature beats and the combined prediction of these indexes is more valuable. Tp-Te interval maybe helpful for prediction of sustained idiopathic VT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10106654PMC
http://dx.doi.org/10.1002/clc.23998DOI Listing

Publication Analysis

Top Keywords

pvc group
20
tp-te interval
16
interval tp-te/qt
16
tp-te/qt ratio
16
qrs-t angle
16
idiopathic ventricular
16
ratio qrs-t
12
ventricular tachycardia
12
tachycardia patients
12
ventricular premature
12

Similar Publications

Background: The relationship between premature ventricular contractions (PVC) and right ventricular (RV) function is not widely known. Left ventricular (LV) dysfunction due to PVC is known as PVC-induced cardiomyopathy (PIC) and suppressing the PVC substrate would improve LV function. The effect of PVC ablation on changes in RV function in patients with subtle RV subclinical dysfunction remains unknown.

View Article and Find Full Text PDF

Objective: To investigate the correlation between premature ventricular contraction (PVC) frequency and heart rate (HR) in Chinese adults, with an emphasis on sex-specific differences in clinical characteristics.

Patients And Methods: This retrospective study analyzed 24-hour Holter monitoring data from 478 inpatients at the First People's Hospital of Yibin between January 2021 and December 2022. The inclusion criteria were age ≥18 years, ≥20 hours of Holter recording, frequent PVCs (≥ 500 PVCs), and complete clinical profiles.

View Article and Find Full Text PDF

Assessing the inhalation hazard of microplastics is important but necessitates sufficient quantity of microplastics that are representative and respirable (<4 µm). Common plastics are not typically manufactured in such small sizes. Here, solvent precipitation is used to produce respirable test materials from thermoplastics polyurethane (TPU), polyamide (PA-6), polyethylene terephthalate (PET), and low-density polyethylene (LDPE).

View Article and Find Full Text PDF

The increasing global demand for plastic has raised the need for effective waste plastic management due to its long lifetime and resistance to environmental degradation. There is a need for rapid plastic identification to improve the mechanical waste plastic sorting process. This study presents a novel application of Temperature-Programmed Desorption-Direct Analysis in Real Time-High Resolution Mass Spectrometry (TPD-DART-HRMS) that enables rapid characterization of various plastics.

View Article and Find Full Text PDF

Trends in the epidemiology of intravascular device-associated bacteremia among French hematology patients: insights from the SPIADI prospective multicenter study, 2020-2024.

Ann Hematol

January 2025

Mission Nationale Surveillance et Prévention des Infections Associées aux Dispositifs Invasifs (SPIADI), Centre d'Appui pour la Prévention des Infections Associées aux Soins en région Centre val de Loire, Centre Hospitalier Régional Universitaire, Hôpital Bretonneau, Tours, France.

Hematology patients require central venous catheters for cancer treatment and nutrition, which increases their risk of intravascular device-associated bacteremia. In the absence of recent data, we investigated intravascular device-associated bacteremia in this specific context. A three-month surveillance was conducted annually in 27 hematology wards, using a protocol derived from the HAI-Net ICU ECDC protocol (2020-2024).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!