Is Orthokeratology Treatment Zone Decentration Effective and Safe in Controlling Myopic Progression?

Eye Contact Lens

The Second Affiliated Hospital, Zhejiang University School of Medicine, Eye Center, Hangzhou, Zhejiang, China.

Published: April 2023

Objective: To compare the myopia control efficacy and safety of decentered versus centered positioning of orthokeratology.

Methods: This is a retrospective intrasubject study, including 46 children with myopia (25 boys, 21 girls; age 11.12±0.33 years) treated for 1 year with OK decentration in one eye (group D) and central location in the other (Group C). Axial length was measured before and at 6 months and 12 months after the initial lens wear, respectively. Corneal topography was measured at baseline and at 1-month after lens wear. The corneal topography obtained from the 1-month visit was used to quantify treatment zone decentration (TZD) for each subject. Cycloplegic refraction was required for all children before fitting the orthokeratology lenses.

Results: No differences were found between the groups in the biological ocular parameters ( P ≥0.05 for all). The axial elongation in group D and group C differed after 6 and 12 months ( P <0.001 for all). Similar corneal staining rates ( P =0.06) were noted during follow-up in groups D (n=20; 7.24%) and C (n=10; 3.62%), all of grade I. The uncorrected visual acuity (UCVA) in group D and C differed after 1, 6, and 12 months ( P =0.002, 0.010, 0.044), except 3 months ( P =0.146). Group D (n=32; 17.39%) was more likely to have glare or ghosting (chi-squared test, P <0.001) than group C (n=12; 6.52%) during follow-up visits. Axial elongation was significantly associated with baseline spherical equivalent (SE) in group C ( P =0.019). In group D, axial elongation was significantly associated with SE and TZD ( P <0.05 for all).

Conclusions: This intrasubject study showed that when the UCVA was acceptable and there were no apparent complications, orthokeratology decentration may be beneficial in controlling the progression of myopia. Axial elongation became slower in children with a higher SE and a larger TZD, because TZD ranged from 0.5 mm to 1.5 mm.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICL.0000000000000981DOI Listing

Publication Analysis

Top Keywords

treatment zone
8
zone decentration
8
lens wear
8
wear corneal
8
corneal topography
8
orthokeratology treatment
4
decentration effective
4
effective safe
4
safe controlling
4
controlling myopic
4

Similar Publications

Purpose: We describe an atypical presentation of an 11-year-old female with enhanced S-cone syndrome (ESCS).

Methods: Case report. The patient underwent a thorough ophthalmic examination and investigations such as colour fundus photography, optical coherence tomography, fundus autofluorescence, fluorescein and indocyanine angiography, an electroretinogram and genetic testing.

View Article and Find Full Text PDF

Objectives: Opioids kill tens of thousands of patients each year. While only a fraction of people with opioid use disorder (OUD) have accessed treatment in the last year, 30% of people who died from an overdose had an Emergency Medical Services (EMS) encounter within a year of their death. Prehospital buprenorphine represents an important emerging OUD treatment, yet limited data describe barriers to this treatment.

View Article and Find Full Text PDF

Purpose: To evaluate changes in the retinal microvasculature using widefield swept-source optical coherence tomography angiography (SS-OCTA) following three anti-vascular endothelial growth factor (anti-VEGF) loading injections for diabetic macular edema (DME).

Methods: Thirty-four treatment-naïve patients with DME received an initial three loading injections, followed by injections on an as-needed basis. Macular ischemia was evaluated based on the foveal avascular zone (FAZ) area, perfusion density, and vessel density on a 3 × 3-mm SS-OCTA image.

View Article and Find Full Text PDF

Biomarkers.

Alzheimers Dement

December 2024

GE HealthCare, Amersham, UK.

Background: The Centiloid method (CL) was introduced as a tracer-independent measure for cortical amyloid load and is now commonly used in Alzheimer's disease (AD) clinical trials. To facilitate its implementation into clinical settings, the AMYPAD consortium set out to integrate existing literature and recent work from the consortium to provide clinical context-of-use recommendations of the Centiloid scale, which has been submitted to the European Medicine Agency for endorsement as a Biomarker Qualification Opinion.

Method: Screening of the literature was performed on the 7/11/23 on PubMed to identify articles mentioning "Centiloid".

View Article and Find Full Text PDF

Purpose: To evaluate dynamic changes in ciliary parameters and Implantable Collamer Lens V4C (ICL) (STAAR Surgical) haptic position using mydriatic and miotic agents and their effects on the central and peripheral vault.

Methods: This study involved 80 eyes from 40 consecutive patients (mean age: 28.05 years; range: 19 to 42 years) examined 3 months after ICL implantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!