A magnetic needle headspace single-drop microextraction (MN-HS-SDME) method coupled to HPLC/UV has been developed. Trihexyl(tetradecyl)phosphonium chloride was employed as an ionic liquid (IL) solvent for the headspace extraction of some chlorophenol (CP) compounds from wastewater samples. Despite of the nonmagnetic character of the IL, a significant improvement in the extraction efficiency was obtained by the magnetization of the single-drop microextraction needle using a pair of permanent disk magnets. A simplex method for the fast optimization of the experimental conditions (e.g., stirring speed, ionic strength, pH, extraction time and temperature) was used. The coefficients of determination (R2) varied between 0.9932 and 0.9989, the limits of detection were from 0.004 to 0.007 μg mL-1 and the relative recoveries were in the range of 88-120% for the studied analytes. The developed MN-HS-SDME HPLC/UV method was successfully applied to the determination of CPs in industrial wastewater.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmad011DOI Listing

Publication Analysis

Top Keywords

single-drop microextraction
12
magnetic needle
8
needle headspace
8
headspace single-drop
8
ionic liquid-based
4
liquid-based magnetic
4
microextraction combined
4
combined hplc/uv
4
hplc/uv determination
4
determination chlorophenols
4

Similar Publications

Traditional Chinese medicine (TCM) is a treasure of China and a crucial part of traditional medicine in the world, particularly in many oriental countries. TCM is the core and basis of traditional medicine in clinical practice for numerous diseases, and performs important function in nutraceuticals and dietary supplements. However, it is extremely difficult to extract each active ingredient from TCM to elucidate the mechanism of TCM clinical efficacy due to numerous compounds in TCM, especially trace compounds.

View Article and Find Full Text PDF

Self-generated single-drop microextraction enhanced aggregation-induced emission strategy based on magnetic metal-organic framework for microRNA-21 detection.

Talanta

February 2025

School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, PR China; Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore. Electronic address:

Lung cancer is one of the most common malignancies with low prevention efficiency and high mortality, so prevention and early detection are very important. In this work, we propose a magnetic metal-organic skeleton nanomaterial bound to biological nucleic acid chains in a spatially confined magnetic single-drop microextraction (SDME) system to enhance the aggregation-induced emission (AIE) effect for fluorescence detection of miRNA-21 associated with lung cancer. DNA/MOF network structure was formed, and loaded with an AIE material, 4',4''',4''''',4'''''''-(ethene-1,1,2,2-tetrayl) tetrakis-([1,1-biphenyl]-3-carboxylic acid) (HETTC), by DNA amplification reaction.

View Article and Find Full Text PDF
Article Synopsis
  • A new method called DI-SDME-OP combines an optical probe with single-drop direct immersion microextraction to effectively concentrate and measure rhodamine 6G (Rh6G) using spectrophotometry.
  • The technique involves forming an ionic associate between Rh6G and picric acid at a specific pH (3.0) and extracting it with amyl acetate, allowing for real-time absorbance monitoring at 534 nm.
  • This method shows comparable sensitivity to other extraction techniques and is more environmentally friendly, achieving a greenness score of 0.58; it has a linear calibration range for Rh6G from 10-500 nM and a low detection limit of 3.4 nM
View Article and Find Full Text PDF

Water, renowned for its sustainability and minimal toxicity, is an ideal candidate for environmentally friendly solvent-based microextraction. However, its potential as an extractant solvent in miniaturized sample preparation remains largely unexplored. This paper pioneers using water as the extraction solvent in headspace single-drop microextraction (HS-SDME) for N-nitrosamines from losartan tablets.

View Article and Find Full Text PDF
Article Synopsis
  • * The technique significantly improves extraction efficiency by increasing the contact area and thickness of the solvent film, while a cooling system ensures that the target analyte condenses in a specific area, minimizing contamination.
  • * Results showed high sensitivity with limits of quantification at 0.1 μg/L and a notable enrichment factor, with successful application to real samples like well water, achieving recovery rates between 92% and 99%.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!