Background: Despite the increasing application of tolvaptan in cardiac surgery, there is no information on the use of tolvaptan in Stanford patients with type A aortic dissection. This study aimed to evaluate the postoperative clinical effects of tolvaptan in patients with type A aortic dissection after tafter surgery.
Methods: A retrospective analysis was performed on 45 patients treated for type A aortic dissection in our hospital from 2018 to 2020. These included 21 patients who were treated with tolvaptan (Group T) and 24 patients who received traditional diuretics (Group L). The hospital's electronic health records were used to obtain perioperative data.
Results: Group T did not differ significantly from Group L in terms of the duration of mechanical ventilation, postoperative blood required, length of catecholamine use, or the amount of intravenous diuretic drugs administered (all P > 0.05). The development of postoperative atrial fibrillation was significantly less in the tolvaptan group (P = 0.023). The urine volumes and change in body weight loss were slightly higher in group T than in group L but the differences were non-significant (P > 0.05). Serum potassium, creatinine, and urea nitrogen levels did not differ between the groups in the week after surgery, At the same time, sodium was significantly higher in the Group T group on day 7 after transfer from the ICU (P = 0.001). In Group L, sodium levels were also elevated by day 7 (P = 0.001). On days 3 and 7, serum creatinine and urea nitrogen levels increased in both groups (both P < 0.05).
Conclusions: Both tolvaptan and traditional diuretics were found to be effective and safe for patients with acute Stanford type A aortic dissection. Moreover, tolvaptan may be associated with reducing the incidence of postoperative atrial fibrillation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9942290 | PMC |
http://dx.doi.org/10.1186/s12872-023-03125-x | DOI Listing |
Ann Thorac Surg
January 2025
Division of Cardiovascular Surgery, University of Pennsylvania, Philadelphia, PA; Leonard Davis Institute, University of Pennsylvania, Philadelphia, PA; Penn Cardiovascular Outcomes, Quality, & Evaluative Research Center, Philadelphia, PA.
Background: This study describes in detail the clinical burden of malperfusion associated with acute Type A aortic dissection (ATAAD) in a large, national cohort and the effect of treatment strategy on outcomes.
Methods: All patients undergoing repair of ATAAD between 2017 and 2020 in the Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database were studied. Malperfusion was defined using STS definitions based on imaging or surgeon's evaluation.
J Vasc Surg
January 2025
Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA. Electronic address:
Objective: As aneurysmal disease is progressive, proximal disease progression and para-anastomotic aneurysms are complications experienced after open infrarenal abdominal aortic aneurysm repair (AAA). As such, fenestrated or branched endovascular repair (F/BEVAR) may be indicated in these patients. Data describing fenestrated endovascular aneurysm repair after prior open repair are limited to institutional databases.
View Article and Find Full Text PDFJ Mol Cell Cardiol
January 2025
Department of Cardiology, Harbin Medical University Cancer Hospital, NHC Key Laboratory of Cell Transplantation, Department of Cardiology, Central Laboratory, The First Affiliated Hospital of Harbin Medical University, Institute of Metabolic Disease, Heilongjiang Academy of Medical Sciences, Heilongjiang Key Laboratory for Metabolic Disorder & Cancer Related Cardiovascular Diseases, Key Laboratories of Education Ministry for Myocardial Ischemia Mechanism and Treatment, State Key Laboratory of Frigid Zone Cardiovascular Diseases (SKLFZCD), Harbin, China. Electronic address:
Unlabelled: Treatment of cancer patients with tyrosine kinase inhibitors (TKIs) often results in hypertension, but the underlying mechanism remains unclear. This study aimed to examine the role of mitochondrial morphology and function, particularly mitochondria-associated endoplasmic reticulum membranes (MAMs), in sunitinib-induced hypertension.
Methods: Both in vitro and in vivo experiments performed to assesse reactive oxygen species (ROS), nitric oxide (NO), endothelium-dependent vasorelaxation, systemic blood pressure, and mitochondrial function in human umbilical vein endothelial cells (HUVECs) and C57BL/6 mouse aortic endothelial cells, under vehicle or sunitinib treatment condition.
Ann Vasc Surg
January 2025
Barts Heart Centre, St. Bartholomew's Hospital, London, UK; Neurovascular Research Laboratory, Faculty of Life Sciences and Education, University of South Wales, Glamorgan, UK; William Harvey Research Institute, Queen Mary University of London, London, UK.
Objective: The primary objective of this study is to quantify the incidence of stroke following cardiac surgery over 17 years at our centre. Additionally, we evaluated the potential risk factors leading to postoperative stroke in these patients.
Methods: Patient characteristics and perioperative data were collected for 24,412 patients undergoing surgery at our centre between January 2005 and December 2021.
J Vasc Surg Cases Innov Tech
April 2025
Department of Radiology and Nuclear Medicine, University Teaching and Research Hospital Lucerne, Luzern, Switzerland.
Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).
Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!