Study Objective: The main objective was to devise an endotracheal intubation formula based on pediatric patients' strongly correlated growth parameters. The secondary objective was to compare the accuracy of the new formula to the age-based formula from Advanced Pediatric Life Support Course (APLS formula) and the middle finger length-based formula (MFL-based formula).

Design: A prospective, observational study.

Setting: Operation.

Patients: 111 subjects age 4-12 years old undergoing elective surgeries with general orotracheal anesthesia.

Interventions And Measurements: Growth parameters, including age, gender, height, weight, BMI, middle finger length, nasal-tragus length, and sternum length, were measured before surgeries. Tracheal length and the optimal endotracheal intubation depth (D) were measured and calculated by Disposcope. Regression analysis were used to establish a new formula for predicting the intubation depth. A self-controlled paired design was used to compare the accuracy of the intubation depth between the new formula, APLS formula, and MFL-based formula.

Main Results: Height (R = 0.897, P < 0.001) was strongly correlated to tracheal length and the endotracheal intubation depth in pediatric patients. New formulae basing on height were established, including new formula 1: D (cm) = 4 + 0.1 × Height (cm) and new formula 2: D (cm) = 3 + 0.1 × Height (cm). Via Bland-Altman analysis, the mean differences for new formula 1, new formula 2, APLS formula and MFL-based formula were - 0.354 cm (95% LOA, -1.289 to 1.998 cm), 1.354 cm (95% LOA, -0.289 to 2.998 cm), 1.154 cm (95% LOA, -1.002 to 3.311 cm), -0.619 cm (95% LOA, -2.960 to 1.723 cm), respectively. The rate of optimal intubation for new formula 1 (84.69%) was higher than for new formula 2 (55.86%), APLS formula (61.26%), and MFL-based formula. (69.37%).

Conclusions: The prediction accuracy for intubation depth of the new formula 1 was higher than the other formulae. The new formula based on height: D (cm) = 4 + 0.1 × Height (cm) was preferable to APLS formula and MFL-based formula with a high incidence of appropriate endotracheal tube position.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jclinane.2023.111079DOI Listing

Publication Analysis

Top Keywords

intubation depth
16
endotracheal intubation
12
formula
9
formula based
8
growth parameters
8
compare accuracy
8
apls formula
8
middle finger
8
formula mfl-based
8
intubation
5

Similar Publications

A novel technique of blindly positioning bronchial blockers for one-lung ventilation: a prospective, randomized, crossover study.

J Cardiothorac Surg

January 2025

Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.

Background: Several methods for blindly positioning bronchial blockers (BBs) for one-lung ventilation (OLV) have been proposed. However, these methods do not reliably ensure accurate positioning and proper direction. Here, we developed a clinically applicable two-stage maneuver by modifying a previously reported one-stage maneuver for successful insertion of a BB at the appropriate depth and direction in patients requiring lung isolation where a flexible bronchoscope (FOB) is not applicable.

View Article and Find Full Text PDF

Background: Previously, a depth of anesthesia bispectral index (BIS™) <45 was considered lowand found to have no clinical benefit. A BIS <35 was considered very low and was not only without evident clinical benefit but also associated with a greater risk of postoperative delirium. We considered the association between BIS and the anesthetic dose of inhalational agents, quantified using the minimum alveolar concentration (MAC) fraction, which was the patient's end-tidal inhalational agent concentration divided by the agent's altitude- and age-adjusted minimum alveolar percentage concentration.

View Article and Find Full Text PDF

Background: Remimazolam is a novel ultra-short-acting benzodiazepine known for its hemodynamic stability over propofol. However, its hemodynamic effects compared to those of etomidate are not well established. This study aimed to determine whether the use of remimazolam is non-inferior to etomidate with regard to the occurrence of post-induction hypotension in patients undergoing coronary arterial bypass grafting.

View Article and Find Full Text PDF

The Impact of BMI on Heart Rate During Suspension Laryngoscopy Operation in Patients With Laryngeal Lesions: A Prospective Cohort Study.

J Voice

December 2024

Department of Otolaryngology Head and Neck Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China. Electronic address:

Objectives: Suspension laryngoscopy can trigger vagal reflexes, leading to a decrease in heart rate, a phenomenon that is more common in patients with a high body mass index (BMI). This study aims to systematically evaluate the effect of BMI on heart rate during suspension laryngoscopy (SL-HR) in patients with laryngeal lesions.

Methods: We employed univariate generalized linear regression and stratified analyses to assess the relationship between BMI and changes in SLHR, adjusting for confounders such as age, gender, intubation type, and depth.

View Article and Find Full Text PDF

Aim And Objectives: This study aims to assess the proficiency of nurses in the neurology department in managing patients with indwelling gastrointestinal canal.

Background: Many critically ill patients in neurology departments require the placement of nasoenteric tubes to provide enteral nutrition. However, in clinical practice, there exists considerable variability in nurses' competencies regarding the management of patients with nasoenteric tubes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!