Catheter ablation as first-line therapy for ventricular tachycardia: is it time for a paradigm shift?

J Interv Card Electrophysiol

University of Pennsylvania, 1 Convention Ave, Philadelphia, PA, 19104, USA.

Published: October 2023

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-023-01502-2DOI Listing

Publication Analysis

Top Keywords

catheter ablation
4
ablation first-line
4
first-line therapy
4
therapy ventricular
4
ventricular tachycardia
4
tachycardia time
4
time paradigm
4
paradigm shift?
4
catheter
1
first-line
1

Similar Publications

Myocardial extracellular volume fraction (ECV) measured via MRI serves as a quantitative indicator of myocardial fibrosis. However, accurate measurement of ECV using MRI in the presence of AF is challenging. Meanwhile, CT could be a promising alternative tool for measuring ECV regardless of sinus rhythm or AF.

View Article and Find Full Text PDF

[Catheter ablation in patients with heart failure-who benefits?].

Herzschrittmacherther Elektrophysiol

January 2025

Klinik für Elektrophysiologie/Rhythmologie, Ruhr-Universität Bochum, Bochum, Deutschland.

Atrial fibrillation (AF) ablation is associated with a lower likelihood of death and surgical heart failure (HF) interventions in patients with HF. This effect is mainly driven by reduced all cause and cardiovascular death following ablation. Ablation also results in improved left ventricular (LV) function, decreased AF burden and AF regression.

View Article and Find Full Text PDF

Abolition of Aorticorenal Ganglia Pacing Responses Improves Denervation Efficacy.

Hypertension

January 2025

Cardiology Department (P.B., X.L., V.T.T., M.A.B., A.V., E.Y., D.M.N., U.P., J.L., S.P.T., P.C.Q.), Westmead Hospital, Sydney, Australia.

Background: Transcatheter renal denervation (RDN) remains inconsistent despite developments in ablation technologies, due to the lack of an intraprocedural physiological end point.

Objective: To identify whether aorticorenal ganglion (ARG) guided RDN using microwave (MW) catheter leads to more consistent denervation outcomes compared with empirical MW ablation.

Methods: Pigs underwent sham procedure (n=8) or bilateral RDN using an in-house built open-irrigated MW catheter.

View Article and Find Full Text PDF

Background: Several studies have demonstrated a notable increase in the incidence of atrial arrhythmias among individuals with atrial septal defect (ASD) occluder. Although the sequential dilation technique has been proposed as the mainstream technique for transseptal puncture with ASD occluder, it is associated with substantial risks and technical difficulties.

Case Summary: We report a patient who underwent catheter ablation for atrial fibrillation and had a large ASD occluder.

View Article and Find Full Text PDF

Unlabelled: There are some reports of atrial screw-in lead perforation, but the entire lead body is rarely exposed outside the right atrium at an early stage of the procedure. A man in his 80s had undergone catheter ablation for atrial fibrillation (AF) and had recurrent AF and tachycardia-bradycardia syndrome with 8.8 s of sinus arrest, which caused presyncope.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!