Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Solitary pulmonary nodules (SPNs) are one of the most common chest computed tomography (CT) abnormalities clinically. We aimed to investigate the value of non-contrast enhanced CT (NECT), contrast enhanced CT (CECT), CT perfusion imaging (CTPI), and dual- energy CT (DECT) used for differentiating benign and malignant SPNs with a multi-institutional and prospective study.
Patients And Methods: Patients with 285 SPNs were scanned with NECT, CECT, CTPI and DECT. Differences between the benign and malignant SPNs on NECT, CECT, CTPI, and DECT used separately (NECT combined with CECT, DECT, and CTPI were methods of A, B, and C) or in combination (Method A + B, A + C, B + C, and A + B + C) were compared by receiver operating characteristic curve analysis.
Results: Multimodality CT imaging showed higher performances (sensitivities of 92.81% to 97.60%, specificities of 74.58% to 88.14%, and accuracies of 86.32% to 93.68%) than those of single modality CT imaging (sensitivities of 83.23% to 85.63%, specificities of 63.56% to 67.80%, and accuracies of 75.09% to 78.25%, all < 0.05).
Conclusions: SPNs evaluated with multimodality CT imaging contributes to improving the diagnostic accuracy of benign and malignant SPNs. NECT helps to locate and evaluate the morphological characteristics of SPNs. CECT helps to evaluate the vascularity of SPNs. CTPI using parameter of permeability surface and DECT using parameter of normalized iodine concentration at the venous phase both are helpful for improving the diagnostic performance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10039475 | PMC |
http://dx.doi.org/10.2478/raon-2023-0008 | DOI Listing |