A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Technical characterisation of digital stethoscopes: towards scalable artificial intelligence-based auscultation. | LitMetric

Digital stethoscopes can enable the development of integrated artificial intelligence (AI) systems that can remove the subjectivity of manual auscultation, improve diagnostic accuracy, and compensate for diminishing auscultatory skills. Developing scalable AI systems can be challenging, especially when acquisition devices differ and thus introduce sensor bias. To address this issue, a precise knowledge of these differences, i.e., frequency responses of these devices, is needed, but the manufacturers often do not provide complete device specifications. In this study, we reported an effective methodology for determining the frequency response of a digital stethoscope and used it to characterise three common digital stethoscopes: Littmann 3200, Eko Core, and Thinklabs One. Our results show significant inter-device variability in that the frequency responses of the three studied stethoscopes were distinctly different. A moderate intra-device variability was seen when comparing two separate units of Littmann 3200. The study highlights the need for normalisation across devices for developing successful AI-assisted auscultation and provides a technical characterisation approach as a first step to accomplish it.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10753976PMC
http://dx.doi.org/10.1080/03091902.2023.2174198DOI Listing

Publication Analysis

Top Keywords

digital stethoscopes
12
technical characterisation
8
frequency responses
8
littmann 3200
8
digital
4
characterisation digital
4
stethoscopes
4
stethoscopes scalable
4
scalable artificial
4
artificial intelligence-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!