Photolithographically defined thin film Au dots were used as micro fiducial markers for digital image correlation (DIC), to enable two-dimensional strain measurement of 200 m-thick LIGA (Lithographie, Galvanformung, Abformung) nickel alloys. Due to the sensitivity of electrodeposited films' microstructure and properties on the processing conditions, characterization of LIGA mechanical properties continues to be necessary for microsystems commercialization. DIC offers advantages over laser-based strain measurement techniques but creating suitable speckle patterns on specimens with dimensions under a millimeter is challenging. The material surface roughness itself is often used as the speckle pattern, or micro- or nanoparticles are applied to the surface. But for materials with highly polished surfaces, such as commercial LIGA alloys, the surface roughness is not always suitable, while application of particles still poses technical challenges in uniformity and reproducibility. We fabricated freestanding tensile specimens, with gauge sections 700 m wide × 3 mm long × 200 m thick, from electrodeposited Ni-10% Co using a commercial LIGA process, and conducted microtensile tests at strain rate 0.001 s. Designing and fabricating arrays of randomly oriented 1.5 m-thick Au dots on the specimens provided a suitable way to obtain full-field surface strains over the entire gauge lengths and was reproducible from one specimen to another. Microfabricated fiducial markers therefore can be a useful surface-preparation approach for investigating micromechanical behavior, particularly plasticity and fracture, of LIGA films using DIC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9925374PMC
http://dx.doi.org/10.1088/2631-8695/abfb10DOI Listing

Publication Analysis

Top Keywords

fiducial markers
12
microfabricated fiducial
8
markers digital
8
digital image
8
liga alloys
8
strain measurement
8
surface roughness
8
commercial liga
8
liga
6
image correlation-based
4

Similar Publications

Objectives: Radiotherapy manages pancreatic cancer in various settings; however, the proximity of gastrointestinal (GI) luminal organs-at-risk (OAR) poses challenges to conventional radiotherapy. Proton beam therapy (PBT) may reduce toxicities compared to photon therapy. This consensus statement summarizes PBT's safe and optimal delivery for pancreatic tumors.

View Article and Find Full Text PDF

Background And Purpose: The aim was to estimate the cost of the external beam radiotherapy (EBRT) in public health care centers in Catalonia (Spain), according to the ESTRO-HERO costing model for 2018.

Materials And Methods: Personnel, equipment, and activity data from 2018 from the 11 RT centers were used, incorporating European mean values adapted to the Catalan context. Secondly, EBRT costs were estimated, incorporating 2023 fractionation technique and scheme usage percentages.

View Article and Find Full Text PDF

Advancements in cryo-EM have stimulated a revolution in structural biology. Yet, for membrane proteins near the cryo-EM size threshold of approximately 40 kDa, including transporters and G-protein coupled receptors, the absence of distinguishable structural features makes image alignment and structure determination a significant challenge. Furthermore, resolving more than one protein conformation within a sample, a major advantage of cryo-EM, represents an even greater degree of difficulty.

View Article and Find Full Text PDF

Verification imaging in prostate MR-only radiotherapy: Are fiducial markers necessary?

Radiography (Lond)

December 2024

Newcastle Upon Tyne Hospitals NHS Foundation Trust, Northern Centre for Cancer Care, Newcastle Upon Tyne, United Kingdom; Newcastle University, Translational and Clinical Research Institute, Newcastle Upon Tyne, United Kingdom.

Purpose/objective: MR-only radiotherapy planning exploits the benefits of MRI soft-tissue delineation, whilst negating the registration inaccuracies caused by MRI CT fusion. Fiducial markers have conventionally been used in prostate radiotherapy to reduce on-treatment image matching variability. However, this is an invasive procedure for the patient, and presents technical difficulties in an MR-only pathway as fiducial markers are difficult to visualise on MRI.

View Article and Find Full Text PDF

Automatic detection of alignment errors in cryo-electron tomography.

J Struct Biol

December 2024

Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain. Electronic address:

Cryo-electron tomography is an imaging technique that allows the study of the three-dimensional structure of a wide range of biological samples, from entire cellular environments to purified specimens. This technique collects a series of images from different views of the specimen by tilting the sample stage in the microscope. Subsequently, this information is combined into a three-dimensional reconstruction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!