A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Point of Care Analysis of Hematology in the Operating Theater - a Prospective Observational Study of Accuracy and Feasibility. | LitMetric

Background: Major surgery entails the risk of severe hemorrhage, and an optimized substitution with red blood cell (RBC) and platelet (PLT) transfusions necessitate rapid test results for RBCs/hemoglobin (HGB)/hematocrit (HCT), and PLTs. The HemoScreen (PixCell Medical, Yokneam Ilit, Israel) is an automated point-of-care hematology analyzer employing image analysis and single-use cuvettes. This study aimed to investigate the correspondence between the HemoScreen and standard laboratory testing (SLT) using the Sysmex XN-9000 in patients undergoing major surgery and to evaluate the feasibility in the operating theater.

Methods: A total of 145 blood samples from 91 adult patients were sampled during abdominal and orthopedic surgery and analyzed on both cell counters. Coefficient of variation (CV) was calculated, Passing-Bablok regression analysis was performed, and Bland-Altman plots were constructed. User experience was assessed through a questionnaire.

Results: The HemoScreen showed imprecision with a CV below 5%. Passing-Bablok regression showed positive proportional and negative constant errors for HGB and HCT, a positive proportional error for PLTs, but no dif-ference for RBCs. Bias in the Bland-Altman plots with limits of agreement: RBCs 0.09 x 1012/L (+/- 0.20 x 1012/L), HGB 1.1 g/L (+/- 8.4 g/L), HCT 0.4 % (+/- 2.6%), and PLTs 28.8 x 109/L (+/- 33 x 109/L). The analyzer was scored easy to use with shorter turnaround times compared to SLT.

Conclusions: The HemoScreen is feasible and provides rapid test results with acceptable accuracy for the evaluated application but the two methods cannot be regarded as interchangeable based on the results in this study.

Download full-text PDF

Source
http://dx.doi.org/10.7754/Clin.Lab.2022.220321DOI Listing

Publication Analysis

Top Keywords

major surgery
8
rapid test
8
passing-bablok regression
8
bland-altman plots
8
positive proportional
8
point care
4
care analysis
4
analysis hematology
4
hematology operating
4
operating theater
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!