Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Radial artery cannulation in young children is challenging. A single-operator laser-assisted ultrasound-guidance system was invented to project the path of the target artery on the skin surface. The hypothesis was that this system would improve the first-attempt success rate of radial arterial cannulation in young pediatric patients relative to traditional ultrasound guidance.
Methods: This single-center, prospective, parallel-group, randomized controlled study enrolled pediatric patients (n = 80, age less than 2 yr) requiring radial artery cannulation during general anesthesia. The participants were randomized into the traditional ultrasound-guidance group or the single-operator laser-assisted ultrasound-guidance group. After inducing general anesthesia, ultrasound-guided radial artery cannulation was performed by two experienced operators. The primary outcome was the first-attempt success rate. The secondary outcomes included the procedure time to success within the first attempt, midmost rate of first attempt, first needle-tip position, and average number of adjustments.
Results: In total, 80 children were included in the analysis. The first-attempt success rate in the single-operator laser-assisted ultrasound-guidance group (36 of 40 [90%]) was significantly greater than that in the traditional ultrasound-guidance group (28 of 40 [70%]; absolute difference, 20% [95% CI, 2.3% to 36.6%]; P = 0.025). The median procedure time to success within the first attempt was shorter in the single-operator laser-assisted ultrasound-guidance group compared with the traditional ultrasound-guidance group (31 s [27, 36 s] vs. 46 s [39, 52 s]; P < 0.001). The incidence of hematoma in the single-operator laser-assisted ultrasound-guidance group (1 of 40, 3%) was significantly lower than that in the traditional ultrasound-guidance group (11 of 40, 28%; P = 0.002). Regarding the initial needle-tip position after skin puncture, the median score (4 [3,4] vs. 2 [2,3]; P < 0.001); position 3, 4, or 5 (38 [95%] vs. 13 [33%]; P < 0.001); and position 4 or 5 (26 [65%] vs. 5 [13%]; P < 0.001) were all in favor of single-operator laser-assisted ultrasound guidance.
Conclusions: Compared with traditional ultrasound guidance, the single-operator laser-assisted ultrasound-guided system is a useful add-on to the ultrasound dynamic needle-tip puncture technique. It improves the first-attempt success rate of radial artery cannulation in children younger than 2 yr by projecting the path of the artery on the skin and provides better procedural conditions (stable ultrasound probe).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ALN.0000000000004534 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!