Numerical simulation of mechanical properties of epiretinal membrane peeling.

Comput Methods Biomech Biomed Engin

School of Energy Power and Mechanical Engineering, North China Electric Power University, Beijing, China.

Published: January 2024

An epiretinal membrane (ERM) is a fibrocellular proliferation on the inner surface of the retina causing blurred and distorted central vision. Surgery is the only effective method for ERM removal. This paper investigated the mechanical properties of ERM peeling using the finite element (FE) method. A FE model of ERM formation on the retina surface was constructed. The failure criterion was applied to the attachment pegs to represent the adhesive force between the ERM and retina. The simulation results were consistent with the experimental data in published research. The maximum peeling force was 4.1 mN at a peeling velocity of 2 mm/s and an angle of 30°. The peeling force was minimum at the peeling angle of 45° and increased with the increase in peeling velocity and Young's modulus of the membrane. The outcome of this paper can improve the safety and efficiency of ERM removal.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10255842.2023.2179365DOI Listing

Publication Analysis

Top Keywords

mechanical properties
8
epiretinal membrane
8
erm removal
8
peeling force
8
peeling velocity
8
peeling
7
erm
6
numerical simulation
4
simulation mechanical
4
properties epiretinal
4

Similar Publications

Quantifying changes in the properties of smoke aerosols under varying conditions is important for understanding the health and environmental impacts of exposure to smoke. Smoke composition, aerosol liquid water content, effective density (ρ), and other properties can change significantly as smoke travels through areas under different ambient conditions and over time. During this study, we measured changes in smoke composition and physical properties due to oxidative aging and exposure to humidity.

View Article and Find Full Text PDF

The widespread reliance on single-use plastics (SUPs) has fostered a global throwaway culture, especially in the food packaging industry, where convenience and low cost have driven their adoption, posing serious environmental threats, particularly to marine ecosystems and biodiversity. Edible and ecofriendly packaging made from millet, specifically sorghum ( () Moench), is a promising solution to mitigate SUP consumption and promote sustainability. This study explores the development of edible sorghum bowls, enhanced through roasting and incorporating 3 g of hibiscus and rose flower powders.

View Article and Find Full Text PDF

Background: Implant fixation is often the cornerstone of musculoskeletal surgical procedures performed to provide bony fixation and/or fusion. The aim of this study was to evaluate how different design features and manufacturing methods influence implant osseointegration and mechanical properties associated with fixation in a standardized model in cancellous bone of adult sheep.

Methods: We evaluated the performance of three titanium alloy implants: (A) iFuse-TORQ implant; (B) Fenestrated Sacroiliac Device; and (C) Standard Cancellous Bone Screw in the cancellous bone of the distal femur and proximal tibia in 8 sheep.

View Article and Find Full Text PDF

Morphological change in an isolated population of red squirrels () in Britain.

R Soc Open Sci

January 2025

Centre for Integrative Anatomy, Department of Cell and Developmental Biology, University College London, London WC1E 6BT, UK.

The mechanical properties of dietary items are known to influence skull morphology, either through evolution or by phenotypic plasticity. Here, we investigated the impact of supplementary feeding of peanuts on the morphology of red squirrels () from five populations in Britain (North Scotland, Borders, Jersey and two temporally distinct populations from Formby (Merseyside)). Stable isotope analysis confirmed dietary ecology in 58 specimens.

View Article and Find Full Text PDF

Cementless fixation in total joint arthroplasty: Factors impacting osseointegration.

J Clin Orthop Trauma

February 2025

Orthopedic Surgery, Brigham & Women's Hospital, Harvard University, Boston, MA, USA.

•The success of cementless fixation in TJA depends on a multitude of factors including biological, mechanical, implant, surgical, and material properties.•Biologic fixation has become the primary mode of fixation for the majority of primary total hip arthroplasty (THA) surgeries done today in the United States (US) due to its low complication rate and superior longevity compared to cemented fixation.•Cementless fixation has yet to gain wider acceptance in total knee arthroplasty (TKA) and hip hemiarthroplasty due to several factors including host bone quality, implant design, and surgical technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?