Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Dielectric-based measurement techniques have been shown to be very effective in determining the properties of various materials. These techniques have been widely used in a variety of fields and applications. Time Domain Transmission (TDT) techniques have grown in popularity because they are practical, non-destructive, provide measurements in real time and produce accurate measurements that are independent of multiple reflections. TDT techniques, on the other hand, are mostly performed with specialized bulky laboratory equipment, such as a Vector Network Analyzer (VNA) which makes TDT measurements prohibitively costly and unpractical. In fact, few works in the literature have reported portable on-site TDT systems. The aim of this paper is to design and implement a dedicated, compact, and low-cost microwave Time Domain Transmission (TDT) sensor for measuring superficial soil dielectric properties on-site. Our sensor uses a time-delay measurement technique over a microstrip transmission line to estimate the dielectric properties of the soil under test. Measurement results show that the computed mean absolute error (MAE) is less than 1.2 when compared to a calibrated dielectric assessment kit (DAK) with soils containing less than 20 % of water ( ), implying that our TDT sensor system can obtain on-site measurements in relatively dry soils with acceptable accuracy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9918410 | PMC |
http://dx.doi.org/10.1016/j.ohx.2023.e00398 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!