Imaging birefringent interferometers are used to measure plasma flow in 2-D via the Doppler shift of a spectral emission line. Applications include plasma physics study in fusion energy experiments and in the Earth's upper atmosphere. We present a new, to the best of our knowledge, method for wavelength calibration that does not require measurement at the rest wavelength of the targeted spectral line, nor measurement using a tuneable laser source. This is useful when such light sources are not available. Fringes measured at known wavelengths from the emission lines of gas-discharge lamps are used to constrain an instrument model which can generate the required calibration data. In the process, optical path difference, dispersion and misalignments are characterized. The "2π ambiguity" of interferogram phase data is handled using circular statistics, allowing the wavelength span of the calibration lines to far exceed the unambiguous measurement range of the instrument. The technique is demonstrated to an accuracy of ±1 pm (±0.7 km/s flow-equivalent) over a 40 nm visible wavelength range.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.473278 | DOI Listing |
Ultrason Sonochem
January 2025
School of Engineering Computing and Mathematics, Oxford Brookes University, Oxford, UK; Department of Materials, University of Oxford, Oxford, UK.
This study experimentally investigates the role of cavitation-induced shock waves in initiating and destabilizing capillary (surface) waves on a droplet surface, preceding atomization. Acoustic emissions and interfacial wave dynamics were simultaneously monitored in droplets of different liquids (water, isopropyl alcohol and glycerol), using a calibrated fiber-optic hydrophone and high-speed imaging. Spectral analysis of the hydrophone data revealed distinct subharmonic frequency peaks in the acoustic spectrum correlated with the wavelength of capillary waves, which were optically captured during the onset of atomization from the repetitive imploding bubbles.
View Article and Find Full Text PDFJ Chromatogr Sci
January 2025
Faculty of Pharmacy, Department of Analytical Chemistry, Istanbul Health and Technology University, Istanbul 34469, Turkey.
This study presents a combination of High Performance Liquid Chromatography (HPLC) and ultraviolet (UV) detection that provides the quantification of agnuside in human plasma specimens. Reverse-phase chromatographic separation was carried out with C18 column (150 mm × 4.6 mm × 5 μm), at 25°C with isocratic elution of the mobile phase containing methanol: 0.
View Article and Find Full Text PDFCytometry A
January 2025
Materials Measurements Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland, USA.
An emulsion of silicone oil droplets in aqueous buffer produces a distinctive series of peaks or resonances in the side scatter histogram in a flow cytometer. As many as 12 peaks are observed in the violet-side scatter channel at 405 nm, with half that number observed in the blue side scatter channel at 488 nm. Using the index of refraction of the oil and buffer, the wavelength of light, and the collection angle and gain of the instrument, we assign the peaks to specific diameters at which Mie resonances occur.
View Article and Find Full Text PDFBMC Chem
January 2025
State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China.
Mn is an essential cation extensively utilized in various industrial processes, including electrolytic manganese production, manganese dioxide manufacturing, and zinc processing. It also poses significant environmental challenges as a primary pollutant in Mn-containing wastewater and hazardous materials. Effective monitoring and control of Mn in these processes are vital for improving resource conversion efficiency and minimizing pollutant production.
View Article and Find Full Text PDFSingle-shot ptychography is a quantitative phase imaging method wherein overlapping beams of light arranged in a grid pattern simultaneously illuminate a sample, allowing a full ptychographic dataset to be collected in a single shot. It is primarily used at optical wavelengths, but there is interest in using it for x-ray imaging. However, constraints imposed by x-ray optics have limited the resolution achievable to date.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!